Descargar Imprimir esta página

Palazzetti ECOFIRE JACKIE IDRO S Serie Manual De Instalación Y Mantenimiento página 18

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ECOFIRE JACKIE IDRO
Overall thermal power (output)
Thermal power to water
Yield
Flue gas temperature
Flue gas flow rate
Hourly fuel consumption
Emissions of CO (at 13% of O2)
Flue gas outlet
Combustion air inlet
Outside air intake
Fuel
Flue draught
Minimum draught for chimney sizing
Stove suitable for rooms no smaller than
Feeding tank capacity
Weight
No. of room fans
Room fan flow rate
Maximum operating pressure
Water content in the boiler
Electrical data
Voltage
Frequency
Max power absorbed during operation
Power absorbed at electric ignition
18
Min
kW
4.6
kW
3.9
%
96.4
°C
59.3
g/s
4.56
kg/h
1
mg/
276
Nm
3
mm
mm
mm
Wooden pellets
Pa
Pa
m
3
kg
kg
no.
m
/h
3
bar
2.5 (200000 Pa)
litres
JACKIE IDRO 20
V
Hz
W
W
004779192 - 05/04/2023
IDRO 20
Max
20
18.9
94.7
114.4
11.28
4.39
66
Ø 80
Ø 60
Ø 100
12 ± 2
0.0
40
27
223
1
100
42.3
220-240
50
45
360

Publicidad

loading