INSTALLATION
CAUTION: Use pipe joint sealant that is resistant to gas (NG). We recommend that you install a
sediment trap in a supply line. Locate sediment trap where it is within reach for cleaning and not
likely to freeze. Install in the piping system between the fuel supply and the gas fireplace insert.
A sediment trap traps moisture and contaminants.This keeps them from going into the gas
fireplace insert controls. If a sediment trap is not installed or is installed incorrectly, the gas
fireplace insert may not run properly.
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting into gas
piping and/or fittings. NG Models: 6 in. to 14 in. W.C. Gas supplier provides external regulator for
natural gas.
Installation Items Needed (Not Provided)
• 8'' Adjustable Wrench
• 8'' Pipe Wrench
• 1/2'' Flexible Gas Line (24'' Min.) or 1/2'' Black Pipe
• 90 Deg. 1/2 NPT x 3/8'' Flare Fitting or 3/8 NPT x 1/2 NPT' Street Elbow
• Sealant (Resistant to Natural Gas)
• Shut Off Valve
• Allen Wrench
1) A variety of options are possible for routing the Gas Connection Lines depending on where
your Gas Supply line is located.
NOTICE: Most building codes do not permit concealed gas connections. Check your local build-
ing code prior to using a Flexible Gas Line for this installation.
2) Identify the gas inlet on the gas fireplace insert. Remove the threaded plug by turning
counterclockwise.
Install a 90 degree fitting - not included). Be sure to use a gas resistant sealant on the 3/8 NPT
fitting. Position the fitting so the inlet line can be attached without binding.
3) Install the Gas Line to the 90 Deg. fitting and attach to the Shut Off Valve.
4) Check all connections for gas leaks.
Natural Gas (NG)
Regulator Inlet
(3/8-18NPT)
To Regulator
Flexible Gas Line or
Black Pipe to Heater
Cabinet Regulator
Fig. 16 - Attaching Flexible Gas Line
to Equipment Shutoff Valve
18
Equipment
Shutoff
Valve
Natural Gas (NG)
To Gas Supply