OPERATING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Push in and turn the control knob clockwise
"OFF" position (See Fig. 25).
3. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Follow
"B" in the safety information above. If you don't smell gas,
go to the next step.
4. Push in and turn the control knob counterclockwise
the "PILOT" position. Depress control knob.
5. Keep the control knob depressed until the pilot lights. The
pilot's location is under the ignition screen. Watch to see if
the pilot lights or not.
• Do not attempt to light the pilot by hand.
6. Keep control knob depressed for (30) seconds after pilot lights. Release the control knob.
• If the control knob does not pop up when released, stop and immediately call a qualified service
technician or gas supplier.
• If the pilot goes out repeat steps 3 through 7. Wait (1) minute before attempting to light pilot again.
If after several tries the pilot still goes out, turn the gas control knob clockwise
position and call a qualified service technician.
7. Turn the control knob counterclockwise
WARNING: Any glass doors shall be completely opened while appliance is in operation.
1. Push in and turn the control knob clockwise
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise
LIGHTING INSTRUCTIONS
to desired setting.
TO TURN OFF GAS TO APPLIANCE
to the PILOT position.
23
LOW
to the
Position
to
HIGH
Position
Fig. 25 - Control Knob