11.6 Set Chime mode
There are 4 different options according to the following configuration:
CHIME TYPE
CHIME OFF
CHIME 1
CHIME 2
CHIME 3
This chime is activated from MIC1 RJ45 connector only. The APS-06 chime is embedded in the
unit itself and it is not affected by this configuration.
11.7 Microphones connection
There are two different inputs for MIC1, one XLR/JACK and one RJ45.
MIC 1 can attenuate, according to the configuration, all other inputs except TEL EMER.
Two working modes are available, mute by contact or by VOX.
Set PTT to ON to activate mute function by contact in RJ45, or PTT to OFF to activate the mute by
VOX control.
If mute by contact is used MIC1 will cut all other MIC inputs and all zones will be activated. In case
of mute by VOX they have to be selected manually.
Activate the Phantom power switch for inputs M1 ~ 6 if the connected microphones requires it.
Select microphone or Line input level for MIC5/LINE1 and MIC6/LINE 2 inputs. LINE sensitivity is
200 mV.
A8000X Series Version 1.4
Serie 8000
5
6
OFF OFF
OFF
ON
ON
OFF
ON
ON
Página 14 de 33