14. A-8240X TECHNICAL SPECIFICATIONS
Power supply
Rated Output Power
Amplifier type
Power Consumption
Frequency response
Distortion
Inputs
100V Input
Outputs
Phantom Power supply
S/N
Chime control
Control inputs
LED Indicators
Volume controls
Level controls
Output volume controls
Switches
A8000X Series Version 1.4
Serie 8000
115 / 230 Vac, 50 / 60 Hz, 24 Vdc
Mic: 60 Hz ~ 15 kHz +1/-3 dB
Aux: 50 Hz ~ 20 kHz +1/-3 dB
MIC 1-6: 1.5 mV, 600 Ω, balanced, connector XLR / JACK and
LINE 1-2: 200 mV, 600 Ω, balanced, XLR / JACK connector
Selectable: MIC5 / LINE1, MIC6 / LINE2
AUX 1: 500 mV, 10 kΩ, unbalanced, XLR / JACK connector
AUX 2-3: 200 mV, 10 kΩ, unbalanced, RCA connector
POWER IN: IV, 600 Ω, unbalanced, RCA connector
Paging Station: 1 V, RJ45 connector
Wall Control Panel: 1 V, RJ45 connector
TEL / EMEG: 300 mV, 600Ω, balanced
Tel / Emer. / 100V, balanced input / Ext Amp In: 100V
REC Out: 1 V, unbalanced, RCA connector
PRE Out: 1 V, unbalanced, RCA connector
Ext. Amp: XLR Connector, balanced
MOH 0 / 8 Ω: 8 Ω, 1 W, unbalanced
MOH 600 Ω: 600 Ω, 1 Vrms, balanced
Direct output: 100 V – 70 V - 8 Ω - 0
Expansion connector: RJ45 connector
Z1-Z6 outputs: 100V – 0
ON / OFF, MIC 1 – 6, 16Vdc
MIC 1 – 4: > 60dB, TEL: > 70 dB / MIC 5 – 6: > 60 dB /
LINE 1 – 2: > 70 dB / AUX 1 – 3: > 75 dB
Bass: ± 10 dB, 100 Hz, Treble: ± 10 dB, 10 kHz
Wall panel: RJ45 connector, operating with AWP-06.
Remote Power: 24 Vdc to turn on the equipment
Zone: A green LED for each zone
Remote / source / Aux 1~3: 5 green LEDs
MIC1~6 / Source / AUX 1~3 / Master
VOX Mute / TEL / MOH / Chime
1~ 6 zones, 6 positions
6 zone switches and 1 switch for All-call
Remote / Source / AUX 1~3 and Turn on
240 W
Analog
720 W
< 1 %
RJ45 (MIC 1)
Vumeter: 4 LEDs
Power: 1 LED
Fail: 1 amber LED.