Descargar Imprimir esta página

Holmatro ICU 40 A Serie Manual página 34

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 71
EN
Description
molykote grease
hose set
pressure gauge set for checking working pressure
leather protection cover for connections between
cutter and hose
8.3
Maintenance schedule
This schedule is an average. Depending on the intensity of use of your equipment, Holmatro can
provide a specific maintenance schedule for you.
/i
Object
General
Hydraulic couplers
Dust caps
Hydraulic hoses
Cutter blades
Hinge pins
Snap ring of the hinge
pins
Centre bolt
Dead man's handle
Carrying handle
1. Holmatro dealer maintenance.
8.4
Maintenance activities
8.4.1
General
Check the operation of the tool.
After every use, check the blades for damage, and if necessary, grind off / file away any burrs that
are visible on the cutting edge.
Check the tool for damage and leaks. If the tool does not work properly and/or leaks, have it
repaired by a Holmatro certified technician.
8.4.2
Hydraulic coupler
Check the couplers for damage. Have a Holmatro Certified Technician replace damaged couplers.
Clean the coupler with luke warm water and a mild soap solution.
34
Action
Check, clean
Check, clean, lubricate
Check, clean
Check
Check
Lubricate
Check
Lubricate
Check
Check
916.000.375_003
Part number
100.581.082
100.570.006
170.182.006
130.183.012
Time interval
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
ICU 40