Replace the Lens
Note
There is no need to restart the product after changing the lens. However, the product must
be restarted if you are interchanging between a P-Iris, DC iris or fixed/manual iris lens. In
order to set the focus and position the lens, the product must be connected to the network.
It is possible to use optional lenses for the Axis product.
To replace the lens:
1. Disconnect the iris cable.
2. Unscrew the standard lens.
3. Attach and screw on the new lens.
Note
If you select a DC iris configuration file for a P-Iris lens, an error message will appear
below the iris configuration type in the Camera Settings page. For custom DC iris lenses,
select Generic DC iris option.
To change the iris configuration:
1. Go to Setup > Video and Audio > Camera Settings. Iris configuration shows the
current configured iris type.
2. Click Edit.
3. Select the installed iris lens from the drop-down list and click OK.
To change the iris configuration for P-Iris lenses not listed in the drop-down list:
1. Download the iris configuration file from www.axis.com
2. Go to Setup > Video and Audio > Camera Settings. Iris configuration shows the
current configured iris type.
3. In Iris configuration: Click Edit.
4. Go to the Upload tab.
5. Click Browse and select the configuration file.
6. Click Upload. The installed iris lens should now be included in the Iris Selection
drop-down list.
7. Select the installed iris lens from the drop-down list and click OK.
Reset to Factory Default Settings
Important
Reset to factory default should be used with caution. A reset to factory default will reset
all settings, including the IP address, to the factory default values.