Descargar Imprimir esta página

IPC CT110 BT85 Manual De Instrucciones página 73

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 133
At the end of charging with
the
electronic
battery
charger, the battery does
not provide the correct
voltage (about 2.14 V per
element without load) and
only one or a few elements
appear flat when tested
with the hydrometer
The
electrolyte
in
battery is turbid
the battery charger does not work
one or more elements are damaged
the
the battery has reached the end of
the
charging/discharging
declared by the manufacturer
the battery has been charged with
too high a current
the
battery has
beyond
the
recommended by the manufacturer
make sure there is voltage to the
battery charger, that the fuses are
not blown and that the current
reaches the battery; try charging
with another rectifier. If the battery
charger is not working, contact the
technical
indicate the serial number of the
battery charger
if possible, replace the damaged
elements.
For 6 or 12 V single block batteries,
replace the entire battery
replace the battery
cycles
replace the battery
been
charged
replace the battery
maximum
limit
service
centre
and
ENGLISH
25

Publicidad

loading

Este manual también es adecuado para:

Ct110 rLavamatic bt815Ct110/ecs178054Ct110 bt60Ct110 bt70 ... Mostrar todo