Battery change
d
Warning: take care not to inverse the polarity + (red) and - (black) when connecting the batteries as this will
l
destroy the device.
Technical characteristics
EATON 3S
UPS power
l
Nominal input voltage
l
Input frequency
l
Voltage/frequency of battery backup
l
outlets 6 in battery mode
Total output current for all outlets
l
Output current of battery backup outlets 6
l
Leakage current
l
Input protection
l
Transfer time
l
Telephone surge protection
l
Sealed lead-acid battery
l
Automatic battery test
l
Average battery life
l
Operating temperature
l
Storage temperature
l
Operating relative humidity
l
Operating elevation
l
Safety standards
l
Electromagnetic compatibility standards
l
Warranty
l
Dimensions (mm)
l
Weigth (Kg)
l
(*) Warning: EATON 3S is a class C2-UPS product. In a domestic environment, these products may cause radio
interference, in which case, the user may be required to take additional measures.
Output cables should not exceed 10 m length.
4
a
550
550 VA / 330 W
184 V - 264 V, adjustable to 161 V - 284 V
50/60 Hz (46 - 70 Hz working range)
220 V / 230 V / 240 V ±7 % (50/60 Hz ±1 Hz)
with pseudosinusoidal wave
2.4 A max
10 A resettable circuit breaker
12 V, 5 Ah
4 years typical, depending on number of discharge cycles and temperature
335 x 140 x 86
3.3
c
b
f
e
10 A max
0.5 mA
5 ms typical
Tel, ISDN, ADSL, Ethernet
Once a week
0 to 40 °C
-25 °C to +55 °C
0 to 85 %
0 to 2000 m
IEC 62040-1, CE certified
IEC 62040-2
2 years
700
700 VA / 420 W
3.1 A max
12 V, 7 Ah
335 x 170 x 86
3.8