container (11) with cold tap water and do not exceed MAX level marked on the plastic container. The content of plastic container is
prohibited to edible. Keep away from children.
1. Place the device on a dry, flat surface. If the surface is not flat, the device can start vibrate and get abnormal noise.
2. Rotate to flat position the water tank lock (13) as shown at pictures C1 and C2. Then, pull out a little the water tank (9) from the back
of the device. Use the jug to pour clear, cold water, be careful not to exceed the maximum level marked at water level gauge (5) at front
of device. You can pour water w/o pulling out the water tank completely. During filling and cleaning, disconnect the device from the
mains.
3. To remove water tank completely look at picture C3-C6. At first remove the pump (15) by releasing one pump latch (14) and pull out
the water tank (8). Do not pull out the pump, let it stay connected to main housing. When you place the water tank (9) back take
attention to not squeeze the water pipes connected to the pump.
After water pouring, turn the water tank lock (13) to horizontal position. Do not tilt the device after pouring the water to water tank. Do not
remove water tank while the device is plug in power supply.
4. Connect the plug to power supply. Now can be used control panel (12) or remote control (10) to operate the device (figure B). Turn on
the device by pressing the power button (A). Press the button (A) again to switch off the device.
5. The button SPEED (C) allows you to change the speed of the fan. The following speeds can be selected: high, middle and slow. The
corresponding diode on the control panel will light up.
6. The air humidification function is operated by COOL button (F), it lowers the temperature of the air by running the water pump. Press
the button (F) when there is water inside water tank ONLY, the corresponding diode will light up on the control panel (12). Additionally, a
set of two plastic containers (11) is attached. Plastic containers (11) should be filled by cold, tap water and do not exceed maximum
level. Next, put them on several hours inside the freezer. Then put one or both of containers into water tank (9). To blow the wet cool air,
the device must be filled with water. When the device is operating, periodically check the water level to see whether to add water. Press
button (F) again to turn off the wet cold air blowing.
7. Pressing the oscillation function by pressing the SWING button (E) to provide even distribution of cold air stream in left and right
direction. The corresponding diode will light up at control panel (12).
8. The TIMER button (D) allows for programming the amount of operation time with 1 hour decrements from 1 to 8 hours. Repeated
pressing of this button will light up a combination of diodes at control panel (12). The sum of lighted up diodes marking means chosen
period the device will operate before switching off the device automatically.
9. The MODE button (B) allows for changing between one of 3 blowing modes:
normal wind, natural wind and sleep mode. Chosen mode diode will light up at control panel (12).
a) Normal Mode: allows the user to manually adjust the speed of fan between high, medium and low.
b) Natural Mode: mimics the natural wind action by repeating the fan speed sequence:
* When choose the low fan speed, the device blows out and repeats below cycle: low 4 seconds + stop 2 second + middle 4 seconds +
low 6 seconds + middle 4 seconds + stop 2 seconds + high 2 seconds + low 6 seconds + middle 4 seconds + low 4 seconds + middle 2
seconds + low 4 seconds + middle 4 seconds + low 4 seconds + stop 2 seconds + high 2 seconds + low 4 seconds + middle 2 seconds.
* When choose the middle fan speed, the device blows out and repeats below cycle: low 4 seconds + middle 6 seconds + low 2
seconds + high 2 seconds +stop 2 seconds +middle 4 seconds +low 4 seconds + middle 4 seconds + low 2 seconds + middle 4 seconds
+ low 4 seconds + high 2 seconds + stop 2 seconds +middle 4 seconds + low 4 seconds + high 4 seconds + stop 2 seconds +middle 4
seconds + high 4 seconds.
* When choose the fast fan speed, the device blows out and repeats below cycle: high 4 seconds + stop 2 seconds + middle 4 seconds
+ high 4 seconds + low 4 seconds + high 2 seconds + middle 4 seconds + high 4 seconds + stop 2 seconds + middle 4 seconds + high 6
seconds + low 4 seconds + high 4 seconds + middle 4 seconds + low4 seconds + high 4 seconds + middle 4 seconds.
c) Sleep Mode: was designed to use the effects of Natural Mode to fall asleep. It will gradually decrease the speed of the fan in 30
minute increments:
* When choose the low fan speed: the fan will run the same as low speed Natural Mode.
* When choose the middle fan speed: the fan will blow 30 minutes at middle speed Natural Mode then switch to low speed Natural Mode.
* When choose the high fan speed: the fan will blow 30 minutes at high speed Natural Mode, next it will switch for 30 minutes at medium
speed Natural Mode, then it will switch to low speed Natural Mode.
REMARK: If you prefer a constant fan speed whilst sleeping, we recommend setting the fan to Normal Mode and selecting low speed.
Use the timer function to set the fan to switch off after an elapsed time (e.g. 1 hour after you are going to bed).
10. All buttons on remote control (10) have got same functions as buttons on control panel (12). Do not place any objects between the
device and the remote control to ensure proper communication between the remote control and the device. To start remote control (10)
operation pull out the installing film. To replace the battery push the release tab on remote control housing as show at picture E. Replace
with a battery of the same type, take attention to place it back in correct pole of polarization, reassemble the battery in reverse order.
CLEANING AND MAINTENANCE
Always unplug the device before you start to clean or add/ drain water or movement of device.
1. After finishing operation, before storing the device for longer time, empty the water tank and clean it and the entire device.
2. Clean with soft, dry cloth. Do not use chemical solvents because they can cause permanent damage or deformation of the device.
3. If the device is not used for three or more months, take the batteries out of the remote control.
4. After long time operation, the cover with net (7) and evaporation filter (8) may be clogged with the dust, which will greatly affect the
device's performance of cooling. If long time the water is no exchanged, there may be mold. We suggest to clean the cover with net (7)
and filter (8) once each 10 days. The filter (8) clean procedure is as below:
a) Unplug the device, pull the back cover (7) by both recess (16) to remove it – look at picture D. To remove the evaporation filter (8) pull
back the filter latch (17), the plastic is flexible and will allow you to take out the evaporation filter (8).
b) Clean the evaporation filter (8) by using a vacuum cleaner. The cover with net (7) should not be rub with hands to avoid net
deformation.
c) Put the filter (8) and the cover with net (7) back in place.
d) Make sure the water tank (8), the filter (5) and the cover with net (7) are replaced in correct position before switching on again. Before
seasonal storage make sure all parts are dry by running the fan mode for 2 hours or shorter to make sure the filter (5) is dry completely.
6