Head Temperature
With this function you can display the temperature in the projector-head (near CMY-filter) in degree
Celsius/degree Fahrenheit.
Software version
With this function you can display the software version of the device.
• Select "Software version" by pressing Up or Down.
• Press the Enter-button, the display shows "V-X.X", "X.X" stands for the version number, e.g. "V-1.0", "V-
2.6".
• Press the Mode/Esc-button in order to return to the main menu.
Lamp Control
Lamp on or off
With this function you can switch the lamp on or off via the Control Board.
• Select "Lamp on or off" by pressing Up or Down.
• Press the Enter-button, the display shows "ON" or "OFF".
• Press Up or Down to select "ON" if you wish to strike the lamp or "OFF" in order to switch it off.
• Press the Enter-button to confirm.
• Press the Mode/Esc-button in order to return to the main menu.
Lamp on by power on
With this function you can select if the lamp will be switched on when switching the power on. Select "ON"
by pressing Up or Down if you wish to enable this function or "OFF" if you don't.
Lamp on via external controller
With this function you can select if you can switch the lamp on via an external controller (DMX-channel 16,
value 40-59). Select "ON" by pressing Up or Down if you wish to enable this function or "OFF" if you don't.
Lamp off via external controller
With this function you can select if you can switch the lamp off via an external controller (DMX-channel 16,
value 60-79). Select "ON" by pressing Up or Down if you wish to enable this function or "OFF" if you don't.
Lamp off no DMX
With this function you can select to switch off the lamp off automatically if there is no DMX signal.
Lamp on at temp.
With this function you can set the inside temperature from which the projector will restrike the lamp after
automatic lamp shutoff.
Lamp off at temp.
With this function you can set the inside temperature at which the projector will automatically switch the lamp
off. Press Up or Down to select the maximum inside temperature between 80 °C and 139 °C. Inside
temperatures below 90 °C are not critical. 90 °C and more should lead to the lamp being switched off. Please
note that the outside temperature should not exceed 45 °C.
54/117