Installation and connection

How to proceed:
 B
1. Assemble the nozzle unit if necessary, and fit it onto the outlet.
– The spray pattern can be changed by the use of different nozzles.
2. As an option: A cord can be attached to the retaining ring on the underside of the unit to anchor the unit to the
ground.
3. Place the unit upright into the water so that it can float.
4. Route the connection cable to the socket.
– Switching on: Connect the connection cable to the mains. The LEDs will light up, the pump and UVC will imme-
diately start operating.
– Switching off: Disconnect the connection cable from the mains.

Remedy of faults

Malfunction
LEDs are not lit
No water flowing out of the nozzle unit, or in-
sufficient or no pump delivery.
The filtering performance of the unit is not sa-
tisfactory.

Maintenance and cleaning

The unit has to be taken out of the water for cleaning or maintenance.
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.

Protective measures:

 Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
 Isolate the unit before starting any work.
 Secure the unit to prevent unintentional switching on.
Cleaning the unit
Note!
Recommendation on regular cleaning:
 Clean the pump as required but at least twice a year.
 Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
 Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
 Clean the outside of the pump.
– Use a soft brush as an aid.
 After cleaning, thoroughly rinse all parts in clean water.
Cause
No mains connection
Connection defective
The nozzle unit is clogged.
The coarse dirt filter is clogged.
The pump filter housing is soiled.
The impeller unit is blocked.
The impeller unit is worn.
Foam filter clogged
The unit has only been in operation for a short
time.
The water is extremely soiled.
The quartz glass is soiled.
The UVC lamp is defective or its capacity is ex-
hausted.
Remedy
Connect the connection cable to the mains.
Check the electrical connection.
Remove and clean the nozzle unit.
Clean the coarse dirt filter.
Clean the pump filter housing.
Clean the pump.
Replace the impeller unit.
Clean or replace the foam filter.
The full biological cleaning effect is only achie-
ved after several weeks.
Remove algae and leaves from the pond,
change the water
Remove the UVC and clean the quartz glass.
Replace the UVC lamp.
- EN -
11