LUM12 HRF
Safety and operating instructions
Safety instructions
Warning
■
Make sure you are familiar with the operating instructions before you use this machine.
■
Before making any adjustments (e.g. setting the torque, changing bits) disconnect the machine from
the compressed air line.
■
The machine, together with any attachments and accessories, must never be used for anything other
than the designed purpose.
■
Use power sockets only. For safe and economic use - replace worn sockets.
■
Check that the power socket is properly fastened - replace the square drive retainer when necessary.
■
Keep your fingers and loose articles (cloths, hair) away from the outgoing shaft.
■
Do not use gloves.
■
Hold the machine correctly and be aware of the reaction force.
■
Check the position of the reversing valve before start.
■
Check the correct clutch function after any adjustment. Decreased air pressure may produce that the
clutch not disconnect properly.
■
Check that the suspension yoke is in good condition and correctly fastened.
■
Use support handle or torque arm at high torque settings or stressed working positions.
General information
EC DECLARATION OF CONFORMITY
We, Atlas Copco Industrial Technique AB, S-105 23 STOCKHOLM, SWEDEN declare that the product
(with name, type and serial number, see front page) is in conformity with the following Directive(s):
2006/42/EC
Harmonised standards applied:
ISO 11148-6
Technical file available from:
Quality Manager, Atlas Copco Industrial Technique, Stockholm, Sweden
Stockholm, 1 July 2013
Tobias Hahn, Managing Director
Signature of issuer
Installation
Installation of vibrating tools
It is recommended that a minimum length of 300 mm of flexible hose for compressed air is inserted be-
tween a vibrating tool and the quick-action coupling.
Air quality
■
For optimum performance and maximum machine life we recommend the use of compressed air with
a maximum dew point of +10°C. We also recommend the installation of an Atlas Copco refrigeration-
type air dryer.
EN
© Atlas Copco Industrial Technique AB - 9836 9378 00
Safety and operating instructions
3