12 VDC timer up to 60 minutes. It has 8 selectable time scales through DIP S1.
Recording every 8 hours in non-volatile memory of the elapsed time.
Operation : When starting the timer, the relay is activated for the selected time, after which the relay is deactivated,
remaining at rest until a new activation.
POWER SUPPLY : Connect the 12 VDC power supply to the POWER terminal, respecting ± polarity. Install a switch
for circuit protection and your own safety, according to CE standard. Before activating the switch, make the rest of the
circuit connections.
To supply 230 V AC you can use our recommended power supplies FE 103 or FE 300.
TIMING : The selection of the work time is done with dips 1-2-3 of S1.
The working time is recorded in the circuit when activating the timer.
It is not possible to change this time once the timing has started. To change it you must deactivate the timer and
select new time.
Activation - Deactivation of the timer : Connect a button to the START input.
Important : Set dip 4 of S1 to ON to activate or deactivate the timer.
Timer activation : close the START button for a moment.
Timer deactivation : keep the START button closed for 2 seconds.
To avoid accidental or malicious manipulations, set dip 4 of S1 to OFF once the timer has been activated or
deactivated.
Work time memory : Every 5 minutes the circuit records in the memory the elapsed working time. Times less than 5
minutes are not recorded to avoid limiting the life of the E2prom memory.
If a power failure occurs during it, the circuit will continue counting from the last recorded time when power returns.
Timer - Temporisateur
Temporizador – Temporitzador
www.cebek.com
-
1 to 60 Minutes
I-209M
Technical characteristics
Voltaje : 12 V DC
Consumption : 10 to 60 mA
Timing configuration : 1 to 60 Minutes
Activation-Reset : Push Button
Output type : Relay NO-NC
Max output load : 7A ( Max 2 A inductive load)
Operation indicator leds : Power – Clock – relay
Sizes 72 x 53 x 20 mm
Weight : 33,2 gr.
Din rail : C-7563
sat@fadisel.com