How to Clean Your Ceiling Fan Blades
Periodic light dusting of the blades is recommended.
A feather duster will work best.
For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan.
Trouble
1. FAN WILL NOT START.
2. FAN SOUNDS NOISY.
3. FAN WOBBLES
EXCESSIVELY.
4. REMOTE CONTROL
DOES NOT WORK. THE
CONTROL INDICATOR
LED IS CONSTANTLY
FLASHING.
5. NOT ENOUGH AIR
MOVEMENT.
Troubleshooting
Probable Cause
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan, or loose
switch wire connections in the switch housing.
3. Dead battery in remote control.
1. Blades not attached to fan.
2. Loose screws in motor housing.
3. Wire connectors inside housing rattling.
4. Motor noise caused by solid state variable speed
control.
1. Setscrew in downrod support is loose.
2. Setscrew in downrod/hanger ball assembly is
loose.
3. Screws securing fan blade to motor assembly are
loose.
4. Hanger bracket and/or ceiling outlet box is not
securely fastened.
1. The battery/batteries are going to run out.
Avoid using water, cleansers, or harsh rags, which
can warp and ruin the blades.
WARNING
1. Check main and branch circuit fuses or circuit
2. Check line wire connections to fan and switch wire
3. Replace with fresh battery.
1. Attach blades to fan before operating.
2. Check to make sure all screws in motor housing
3. Check to make sure wire connectors in switch
4. Some fan motors are sensitive to signals from
1. Tighten both setscrews securely in downrod support.
2. Tighten the setscrew in the downrod/hanger ball
3. Check to be sure screws which attach the fan blade
4. Tighten the hanger bracket screws to the outlet box,
1. Please replace the battery/batteries.
1. If possible, consider using a longer downrod (not
17
Suggested Remedy
breakers.
connections in the switch housings.
CAUTION: Make sure main power is turned off !
are snug (not over-tight).
housing are not rattling against each other or
against the interior wall of the switch housing.
CAUTION: Make sure main power is turned off !
solid-state variable speed controls. Solid-state
controls are not recommended, choose an
alternative control method.
assembly.
to the motor assembly are tight.
and secure outlet box.
included, you can buy the longer downrod from
fanimation.com).

Publicidad

loading

Este manual también es adecuado para:

5127870