b. Keep the generator running for another 1-2 mins before connecting loads to the unit.
CONTROL PANEL INTRODUCTION
FIG. 11
1. AC Receptacle (other sockets available) which supplies rated output.
2. Safety ground terminal.
3. Electronic engine switch.
4. Oil pressure alarm indicator(Red).
a. It will start flashing when the engine starts with insufficient amount of engine oil.
b. It glows in red indicating oil level below the safe limit before the engine automatically shuts down
within 10 seconds.
5. Output indicator light (green) will remain ON during the operation. However, when the green light starts
flashing:
a. Interval Flash 1 time, low-voltage protection, engine speed low.
b. Interval Flash 2 times, high temperature protection.
c. Interval Flash 3 times, overload protection, too many loads.
d. Interval Flash 4 times, short-circuit protection.
The output power will be cut off should the generator is experiencing any of the faults that are mentioned
above. User will need to stop the engine to fix the issue before restarting the engine.
DC Charger socket and overcurrent protector reset-button (Optional).
The DC charger supplies 12-20 VDC pulse voltage with maximum current of 3A. Note it CANNOT be
used as a voltage-stabilized power source. When loads over 3A, overcurrent protector will jump in and
button will pop-up while the output is cut off.