Safety precaution
Caution: Electric shock risk
Always switch off power supply
before repairing on the heat pump
and stop the hydraulic circuit.
- The swimming pool heat pump must be installed by a qualified electrician.
- Always install a leakage protective device with a sensitivity of 30 mA in the power
distribution unit before the electrical box.
- Always fit a circuit breaker for all active conductors on the power supply of the box.
- In case of abnormal behavior (noise, smell, smoke), cut off the power supply immediately
and contact you reseller. Do not attempt to repair the system yourself.
- Keep the main power switch away the reach of children.
- Rotating parts: Never remove the grid from the fan. Never place your hand or any other
object in the air inlet or outlet of the heat pump.
Important features of this product
This swimming pool heat pump is equipped with protection program that
will automatically stop to protect your unit automatically and display
error code on the LED controller in case of some issues as following:
Water Flow Switch
The water flow switch will deactivated when pool water flows through the titanium heat
exchanger. Low flow rates as well as no water flow will activate the water flow switch, the
unit will shut down. The LED controller will display "EE3" if the water pressure is insufficient.
High / Low Refrigerant Pressure Switches