Do not leave the measuring head in the open air more than a few minutes, in order to avoid early alteration.
Always keep the original cap as you will have to keep the probe with water in it, in case of dismantling.
1.4 DESIGN STANDARDS
Directives CE – BT 73/23/CE & CEM 2004/108/CE
Electric standard : NF C 15-100, 702 (for France)
Electric safety : EN 60335-1 : 2003 (for France)
Electromagnetic compatibility : EN61000-6-1:2001; EN61000-6-3:2001/A11:2004
Electrical and electronic equipment wastes : WEEE
Dangerous material restriction : RoHS
1.4 TECHNICAL FEATURES
Electrical specifications :
230V - 50Hz - Double insulation.
Fuses characteristic :
F 300mA L 250V – Dimension 5x20
Environmental conditions :
Indoor use only
Altitude up to 2000m
Temperature from 5 to 40°C
Maximal relative humidity : 80% for temperature going up to 31°C, with linear decrease up to 50% of relative
humidity at 40°C
Ups and downs of the mains voltage should never excess +7% / -10% of nominal voltage.
2.0 TECHNICAL CHARACTERISTICS
2.1 DIMENSIONS
16.5 cm
13 cm
2.2 FUNCTIONING PRINCIPLE
The probe is analyzing continuously the pH or Redox value of water, the requested value (set point) must be
entered by the professional or the pool user.
Those data are then registered by the proportional regulator, allowing or not the rotating movement of the
roller and the injection of the liquid that will equilibrate (pH model) or disinfect (Rx model) the pool water.
2.2.1 REGULATION PRINCIPLE
This dosing pump features a proportional regulation. When the read value is approaching the set point, injection
will be slower, in order to bring comfort to the bathers, and save on chemical products by limiting strong
fluctuations and overconsumption.
3.0 INSTALLATION
3.1 WALL INSTALLATION
Do not install the pump right above the dosing tank (presence of liquids that emanate corrosive fumes).
Install the pump in a dry, ventilated and temperate place (5-40°C), far from any hot source, at a maximal height
of 1.5m above the lower level of chemical solution to inject .
Install the control panel out of reach of children.
Mixy Link comprises 2 boards :
including a 2-pole moulded plug + the pump board. They can be installed on 2 different ways,
The display board
using the 3m connecting cable :
- Linked
- Separate, in that case saw off the wall mounting part at the lugs level.
100897- indB – 0209
13 cm
10 cm
16 / 40
12 cm