Descargar Imprimir esta página

HP 3PAR StoreServ 7450 Guía De Solución De Problemas página 42

Ocultar thumbs Ver también para 3PAR StoreServ 7450:

Publicidad

Formato de posibles mensajes de excepción de nodo
Node node:<nodeID> "Node is not online" Node node:<nodeID> "Power supply <psID>
detailed state is <status> Node node:<nodeID> "Power supply <psID> AC state is
<acStatus>" Node node:<nodeID> "Power supply <psID> DC state is <dcStatus>" Node
node:<nodeID> "Power supply <psID> battery is <batStatus>" Node node:<nodeID> "Node
<nodeID> battery is <batStatus>" Node node:<priNodeID> "<bat> has not been tested
within the last 30 days" Node node:<nodeID> "Node <nodeID> battery is expired" Node
node:<nodeID> "Power supply <psID> is expired" Node node:<nodeID> "Fan is <fanID> is
<status>" Node node:<nodeID> "Power supply <psID> fan module <fanID> is <status>"
Node node:<nodeID> "Fan module <fanID> is <status> Node node:<nodeID> "Detailed State
<state>" (degraded or failed)
Acción sugerida para los nodos (general)
En condiciones de error de nodo, examine el nodo y los estados de los componentes del nodo
con comandos como shownode, shownode -s, shownode -d, showbattery y showsys
-d.
Ejemplo de nodo 1
Component -Identifier- ---------------Description---------------- Node node:0
Power supply 1 detailed state is DC Failed Node node:0 Power supply 1 DC state is
Failed Node node:1 Power supply 0 detailed state is AC Failed Node node:1 Power supply
0 AC state is Failed Node node:1 Power supply 0 DC state is Failed
Acción sugerida para el nodo 1
Examine los estados de los suministros eléctricos con comandos como shownode, shownode
-s, shownode -ps y similares. Encienda o sustituya el suministro eléctrico que falla.
NOTA:
En el siguiente ejemplo, el estado de la batería se considera Degradado ya que el
suministro eléctrico presenta errores; esto es normal.
cli% shownode Control Data Cache Node --Name--- -State-- Master InCluster
---LED--- Mem(MB) Mem(MB) Available(%) 0 1001356-0 Degraded Yes Yes AmberBlnk 2048
8192 100 1 1001356-1 Degraded No Yes AmberBlnk 2048 8192 100 cli% shownode -s Node
-State-- -Detailed_State- 0 Degraded PS 1 Failed 1 Degraded PS 0 Failed cli% shownode
-ps Node PS -Serial- -PSState- FanState ACState DCState -BatState- ChrgLvl(%) 0 0
FFFFFFFF OK OK OK OK OK 100 0 1 FFFFFFFF Failed -- OK Failed Degraded 100 1 0 FFFFFFFF
Failed -- Failed Failed Degraded 100 1 1 FFFFFFFF OK OK OK OK OK 100
Ejemplo de nodo 2
Component -Identifier- ---------Description------------ Node node:3 Power supply
1 battery is Failed
42
Detección y solución de problemas

Publicidad

loading

Este manual también es adecuado para:

3par storeserv 7450c