TROUBLE SHOOTING CHECK LIST
Before asking for a technical assistance service, please follow this list to try to solve most common problems:
PROBLEM
The machine does not work
Working temperature
not sufficient
Egg-turner device not
working properly
Forced ventilation not sufficient
Interior lighting not working
Thermometer alcohol
column interrupted
Dial hair hygrometer
not working properly
(ref. analogue version)
Whichever reparation attempt not included on above mentioned form is severely forbidden. Contact always the manufacturer
or the authorized technical assistance in your country.
Fiem s.r.l. - Ph: 0039 (0)31 976672 - Fax: 0039 (0)31 899163 - fiem@fiem.it - www.fiem.it
22
CAUSE
Lack of power
Plug disconnected
Master switch "0/I" on position "0"
Any of the above points
Heating element not correctly working
Thermostat not calibrated
Thermostat faulty or not working
Door open or incorrectly closed
Egg-turner motor broken
Egg turning grid not connected to
the egg turning motor metal peg
Fan not working
3
Switch on "0" position
Lamp burnt
Accidental drops
Dial hair hygrometer improperly
calibrated
SOLUTION
Check the plug
Put the plug into the socket
Position the switch on "I"
Contact the assistance service
Contact the manufacturer
See instruction for calibration
Contact the manufacturer
Close the door
Contact the manufacturer
Connection the turning grid metal stir
rup to the peg of the egg turning motor
Contact the manufacturer
Place the switch on "I" position
Replace the lamp as shown
in the instructions
Try to put the thermometer at low
temperature for few minutes,
otherwise replace the thermometer
Follow the instructions regarding
synthetic hair hygrometer regeneration
contained on the "positioning &
preparation" paragraph.