Mobile EV Charger EVSE User Manual
Table 1: Front Panel LED Information
Amber
#
POWER
1
off
ON
2
3
ON
4
ON
5
off
6
off
7
off
8
off
9
off
10
off
Red
Green
FAULT
CHARGING
off
off
off
off
off
ON
ON - not
off
blinking
ON - not
off
blinking
1 - blink
off
2 - blinks
off
3 - blinks
off
4 - blinks
off
5 - blinks
off
Fault Condition
No power to the EVSE. Check circuit breaker.
EVSE has power, not plugged into PEV, or
PEV not requesting a charge.
Charging enabled, power is supplied to the
vehicle.
Ground monitor trip, improper grounding or
ground is not present. Call an electrician.
PEV Pilot communication out of spec,
disconnect from vehicle and reconnect.
PEV ground fault trip. Check vehicle
connection, disconnect and restart.
Internal EVSE Fault. Disconnect from vehicle, turn power
off and then back on. If fault persists, call for service.
Internal EVSE Fault. Disconnect from vehicle, turn power
off and then back on. If fault persists, call for service.
Internal EVSE Fault. Disconnect from vehicle, turn power
off and then back on. If fault persists, call for service.
Internal EVSE Fault. Disconnect from vehicle, turn power
off and then back on. If fault persists, call for service.