Descargar Imprimir esta página

EINHELL TE-AC 270/50 Silent Plus Manual De Instrucciones Original página 15

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 75
Compressor
Intake air filter (2x)
Wheel (2x)
Supporting foot (2x)
Transport handle
Hexagon key 5 mm
Socket head screw for handle (4x)
Hexagon screw for supporting foot (2x)
Washer for supporting foot (2x)
Nut for supporting foot (2x)
Wheel cap (2x)
Axle screw (2x)
Washer (2x)
Spring washer (2x)
Nut (2x)
Original operating instructions
Safety instructions
3. Proper use
The compressor is designed to generate com-
pressed air for compressed air driven tools.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection: ................. 220 -240 V ~ 50 Hz
Motor rating: ............................................. 1500 W
Compressor speed rpm: .............................. 1450
Operating pressure bar: ............................ max. 8
Pressure tank capacity (in liters): ................... 50
Theoretical suction rate l/min.: ..................... 270
Output rate (compressed air)
at 7 bar: ............................................ 93 liters/min
Output rate (compressed air)
at 4 bar: .......................................... 132 liters/min
Anl_TE-AC_270-50_Sil_Pl_SPK13.indb 15
Anl_TE-AC_270-50_Sil_Pl_SPK13.indb 15
GB
Sound power level L
WA
Uncertainty K
...................................... 3 dB(A)
WA
Sound pressure level L
Uncertainty K
...................................... 3 dB (A)
pA
Protection type: ............................................ IP20
Weight of the unit in kg: .............. approx. 41,5 kg
Noise
The noise emission values were measured in ac-
cordance with EN ISO 3744.
5. Before starting the equipment
Before you connect the equipment to the power
supply make sure that the data on the rating plate
are identical to the supply voltage.
Check the equipment for damage which may
have occurred in transit. Report any damage
immediately to the transport company which
was used to deliver the compressor.
Install the compressor in the vicinity of the
point of consumption.
Avoid long air lines and supply lines (extensi-
on cables).
Make sure that the intake air is dry and dust-
free.
Do not install the compressor in a damp or
wet room.
The compressor may be used only in suitable
rooms (with good ventilation and an ambient
temperature from +5 °C to 40 °C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor
in areas where work is conducted with spray-
ed water.
Operate the equipment only on a firm, level
surface.
Use flexible hoses in order to prevent trans-
mitting unacceptable loads to the pipeline
system at the connection between the com-
pressor system and the pipeline system.
It is essential to use separators, traps and
drains which process the liquids produced by
the compressor before the compressor sys-
tem is put into operation.
Supply hoses at pressures above 7 bar
should be equipped with a safety cable (e.g.
a wire rope).
- 15 -
in dB(A): ..................... 78
in dB(A): ................. 54
pA
12.06.2023 11:02:26
12.06.2023 11:02:26

Publicidad

loading

Este manual también es adecuado para:

40.206.20