General
Caution
The flat pleated filter must must always be
in place while vacuuming.
If wet dirt is vacuumed with the uphol-
–
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.
If the maximum liquid level is reached
–
the appliance will turn off automatically.
In case of non-conductive liquids
–
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
After the wet vacuuming: Clean the flat
–
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.
Clip connection
Illustration
The suction hose is equipped with a clip
system. All C-40/C-DN-40 accessories can
be connected.
Operation
Rotating knob
–
–
–
–
–
14
Appliance ON
Filter dedusting OFF
Appliance OFF
Appliance ON
Filter dedusting ON
Turning on the Appliance
Plug in the main plug.
Switch on the appliance at the rotating
knob.
Automatic filter cleaning
The appliance has an innovative dual filter
cleaning system that is particularly effective
with fine dust. The flat pleated filter is auto-
matically cleaned every 7.5 seconds
through an air jet (pulsating sound).
Turn off the appliance
Switch off the appliance at the rotating
knob.
Pull out the mains plug.
After each operation
Empty the container.
Vacuum and wipe the appliance inside
and outside with a damp cloth.
Fold the push handle in/out
Loosen the fastening screws of the
pushing handle and adjust the pushing
handle.
Storing the Appliance
Illustration
Store the suction hose and the mains
cable as shown in the illustration.
Place the appliance in a dry room and
secure it from unauthorized use.
– 3
EN