Maximum Operating Temperature
Thermal Temperature Limits:
Maximum water temperature: 104 °F (40 °C).
Maximum shut-off temperature: 150 °F (65 °C)
Minimum reset temperature: 118 °F (48 °C)
In the event of inadequate water supply, such as closure of the incoming water supply or system component
failure, the unit has a potential to run continuously. This operation allows for heating of the water inside the
system. To reduce the amount of heating, the system is equipped with a thermal cutoff switch.
Refer to
"Troubleshooting" on page 14
matically resume operation.
System Pressure Fluctuations
Although the pressure is constant at the pressure sensor, pressure drops may be noticeable in other areas of
the home when additional taps are opened. This is due to restrictions in the plumbing and will be more pro-
nounced the farther the taps are from the pressure sensor. This would be true of any system, and should not
be interpreted as a failure in the performance of the system. Refer to
page
12.
Example
A small demand on the system, such as a bathroom faucet, results in the motor/pump running at its
lowest speed.
As greater demands are placed on the system, such as opening additional faucets or using appliances,
the speed increases accordingly to maintain the desired system pressure.
Status Display
The system provides basic feedback regarding the systems current operational
state, transmitted through the LED.
Item
LED
Green Solid
1
Green Flashing
2
Yellow Solid
3
Red Flashing
for fault codes. Once the system cools, the unit will auto-
Possible Cause
Pump is idle waiting for demand.
Pump is running.
Insufficient water supply.
Service unit. Refer to
"Troubleshooting" on
page 14
for more information.
Maximum Operating Temperature
"Adjusting System Pressure" on
1
2
3
OPERATION
11