Low Cut Filter
Set DIP Switch 4 up to activate the low cut filter. Attenuates 6 dB per octave below 150 Hz.
Local Mute Control
The mircophone ships configured for local (manual) mute control
(DIP Switch 3 down). In this mode, the PUSH button on the micro-
phone mutes the audio signal at the microphone. Audio is not sent
to the audio outputs.
In this configuration, the LED color reflects the microphone state, as
controlled by the user with the PUSH button.
Green: microphone active
Red: microphone muted
Button Configuration
For local mute control operation, use DIP Switches 1 and 2 to configure the button behavior.
Button Behavior
Momentary: push-to-mute (as
shipped).
Momentary: push-to-talk
Toggle: Push and release to
toggle the microphone on or
off. Mic is active when pow-
ered on.
Toggle: Push and release to
toggle the microphone on or
off. Mic is mute when powered
on
6
All manuals and user guides at all-guides.com
SWITCH OUT Logic Signal
When pushed, SWITCH OUT
(red wire) falls to 0 V. When re-
leased, SWITCH OUT returns
to +5 V.
Push and release sets
SWITCH OUT to 0 V. Push
again to toggle back to +5 V.