To start working, proceed as follows:
1.Make all the checks indicated in "PREPARING THE MACHINE".
2.Free the vacuum head from the collection tank by releasing the hooks (1) on the side of the tank. Ro-
tate the levers as shown by the arrow in the picture on the right.
3.Use the handle (2) on the vacuum head unit to remove it from the collection tank.
4.Rest the head carefully on the ground.
5.Make sure the float unit is inserted in the collection tank. If this is not the case, position it correctly.
ATTENTION: there must be no solid waste
residue inside the collection tank.
6.Use the handle (2) on the vacuum head unit to position it above the collection tank.Make sure the
machine's power supply cable is in the rear part of the tank.
7.Fix the vacuum head to the collection tank by coupling the hooks (1) on the side of the tank. Rotate
the levers as shown by the arrow in the picture on the right.
8.Insert the plug (3) of the power cable (4) in the mains socket (5).
9.Switch on the machine by bringing the main switch (6) to the work position "I".
10.Carry out the cleaning work.
ATTENTION: if the vacuuming intensity dimi-
nishes while you are working, read "IMPRO-
VING THE VACUUMING CAPACITY".
The machine is fitted with a mechanical device (float) under the vacuum lid. When the collection
tank is full, this device shuts off the air to the vacuum motor to protect it; you will recognise this
condition by the deeper noise made by the motor. When you hear this sound, you must empty
the collection tank (read "EMPTYING THE COLLECTION TANK").