operator. It gives detailed information in the form of pattern,
codes and number.
8.2.10.
DIGITAL DISPLAY
1
2
4
#
Name
Meaning
1
Battery remaining capacity
2
Time signal
3
Controller fault/ battery fault/ motor
fault/ vehicle fault
4
Fault position
5
Fault code/ total working hours
8.2.11 FAULTS
The Canbus system will take action to protect the user and
machine when it detects an issue. When it acts to turn off the
machine or a component, it will indicate that a fault has
occurred, and that fault will be shown on the digital display.
All electrical faults have a letter code followed by a number.
The first letter describes the system that caused the fault
according to this chart:
T
Traction Controller and motor
PMU
Power management unit (in the battery cab-
in)
MR
Right Blade Controller and motor
ML
Left Blade Controller and motor
9
APP OPERATION TIPS
9.1
MOBILE APPLICATION
Find the serial number, pairing code and QR code in the vehicle matching label on your QUICK START GUIDE.