B
Product usage
Using an interconnection cable (signal cable) and DMX connector
DMX mode
DMX is an operating mode which enables the unit to be controlled via an external controller.
Connect the signal cable from the controller output to the first light's DMX input.
Connect another signal cable from the DMX output of the first light to the DMX input of
the second light.
Repeat the above step to connect all the slave lights.
Connect the last light by connecting the signal cable to the DMXoutput connector.
Please note : the starting address for this mode must be set.
Master/slave mode
Master/slave is an operating mode that allows one light to act as a master and therefore,
control all the other lights as slaves.
Connect the signal cable to the DMX output connector of the first master light and the
DMX input connector of the second slave light.
Repeat the step to connect all the slave lights.
Connect the last slave light by connecting the signal cable to its DMX output connector.
For more information regarding the master and slave mode settings, please refer to the
table above.
Please note : only one light can be set as the master.
DMX address settings
Each light should be set with a specific starting address code. The address can be set as
indicated below.
Setting multiple lights with the same address code.
– The lights will accept DMX512 channel starting signals from the same address code.
– All connected lights will be controlled together.
Setting an independent address code for each light.
Please note: this is an 8-channel light fitting. If the starting address code for the first light
is set to 1, then the starting code for the second light should be 9. The third should be 17,
and so forth. Follow this rule to set the starting address code for each connected light.