Material
Copper
* Typical values for damping with a reference target of 45 x 45 x 1 mm and non-flush
installation to IEC 60947-5-2 at an ambient temperature of 20 °C�
Depending on the characteristics of the damping element there may be no
close zone�
6 Installation
The unit is non-flush mountable according to IEC 60947-5-2, type I2A30SP2�
► Ensure the unit cannot work loose (tightening torque ≤ 50 Nm).
► Adhere to the installation conditions in accordance with the figures 1 to 3:
1
30
► Tighten the socket according to the manufacturer's indications� Observe the
socket tightening torque 0�6���1�5 Nm�
Flush installation of the fail-safe sensor is not permitted since this can result
in an increase of the sensing range up to enabling of the outputs (OSSDs)�
6.1 Protection against simple defeating
The fail-safe sensor reacts to metal objects, e�g� the frame of a safety door� Other
metal objects that are not intended to enable the sensor must not be allowed to
enable the fail-safe sensor unintentionally�
► Take measures to prevent metal objects, except the designated target,
from being placed on the sensing face or in the enable zone unintentio-
nally�
Enable zone
0���5�5 mm
2
45
30
120
3
60
UK
7