6.5 G "Main" Menu
(Ft-lb or Nm selected)
(See Screens 7A and 7B) If Automode
is ON, and a unit of torque has been
selected, the screen text will alternate
between the selected torque wrench
model and "AUTO". Refer to QRC
step #4B.
(See Screens 7A and 7C) If Automode
is OFF, the screen text will alternate
between the selected torque wrench
model and "READY".
Whether Automode is ON or OFF, the
actual torque value (based on system
pressure) will appear on the numeric
display. It will remain at "0" until pump
motor is started.
6.5 H "Main" Menu (PSI, BAR
or MPa selected)
(See Screen 8A) If Automode is ON,
and a pressure unit has been selected,
the screen will display "AUTO". Refer
to QRC step #4D.
(See Screen 8B) If Automode is OFF,
the screen will display "READY".
Whether Automode is ON or OFF, the
actual system pressure will appear on
the numeric display. It will remain at
"0" until pump motor is started.
6.5 I "Motor" Menu
(See Screen 9) This screen allows the
operator to read the number of hours
or on/off cycles the motor has been
operated. Toggle between hours and
cycles by pushing either the Down
or Up Arrow button. Step forward by
pressing the Menu button. Refer to
QRC step #5.
____________________________________________________
__General note for all hour and cycle displays:
HOURS DISPLAYED
- up to 9999.9 the display will show decimal hours.
- between 10,000 - 99,999 whole hours will be
displayed (decimal "." is not displayed).
- over 99,999 hours the meter starts over at 0.0 reading
decimal hours.
CYCLES DISPLAYED
- over 99,999 cycles the meter starts over at 0.
______________________________________________________
Screen 7A
RSL 2
0
Ft-lb
Screen 7B
AUTO
0
Ft-lb
Screen 7C
READY
0
Ft-lb
Screen 8A
AUTO
0
PSI
Screen 8B
READY
0
PSI
Screen 9
MOTOR
4.8
HOURS CYCLES
7
6.5 J "Low Volt" Menu
(See Screen 10) This screen allows
the operator to read the number of
hours the pump has been operated in
a low-voltage condition. Step forward
by pressing the Menu button. Refer to
QRC step #6.
6.5 K "Advance" Menu
(See Screen 11) This screen allows
the operator to read the total number
of hours that the valve solenoid has
been in the advance position. It also
displays the total number of advance
cycles. Toggle between hours and
cycles by pushing either the Down or
Up Arrow buttons. Step forward by
pressing the Menu button. Refer to
QRC step #7.
6.5 L "Retract" Menu
(See Screen 12) This screen allows
the operator to read the total number
of hours that the valve solenoid has
been in the retract position. It also
displays the total number of retract
cycles. Toggle between hours and
cycles by pushing either the Down or
Up Arrow buttons. Step forward by
pressing the Menu button. Refer to
QRC step #8.
6.5 M "Local" Menu
(See Screen 13) This screen allows the
operator to toggle the Local mode ON
or OFF (default is OFF). Local mode
allows operation of the pump if the
pendant or pendant cord is damaged.
With Local mode ON, the shroud
buttons replace the pendant buttons
as the method of operating the pump,
and the pendant buttons become deactivated. Toggle Local
mode ON or OFF by pressing the Down or Up Arrow button.
When Local mode is ON, the text "LOCAL" replaces "READY"
on the Normal Operation menu. Save setting and step forward
by pressing the Menu button. Refer to QRC step #9.
6.5 N "Language" Menu
(See Screen 14) This screen allows
the operator to change the LCD display
language. When a language is shown on
the LCD, press the Down or Up Arrow
buttons to select a different language.
Save setting and step forward by pressing
the Menu button. Refer to QRC step #10.
Screen 10
LOW VOLT
.0
HOURS
Screen 11
ADVANCE
188
HOURS CYCLES
Screen 12
RETRACT
334
HOURS CYCLES
Screen 13
LOCAL
SET
OFF
Screen 14
ENGLISH
SET