Descargar Imprimir esta página

Enerpac ZU4 Serie Hoja De Instrucciones página 8

Ocultar thumbs Ver también para ZU4 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

6.5 O "Diagnose" Menu
(See Screen 15) This screen allows
the operator to troubleshoot various
pendant problems. If the number "1"
does not appear when a pendant
button is pushed, problems with
the pendant button switches and/or
pendant cord may be present (See
Screens 16 and 17). Use Local mode
to operate pump until the problem can
be corrected. Refer to QRC step #11.
Pendant on/off button
Pendant advance button
(not used
on this pump
version)
Diagnose screen
with pendant
on/off button
pushed.
Diagnose screen
with pendant
advance button
pushed .
6.5 P "Calibration" Menu
(See Screen 18) This screen allows
the operator to adjust the pressure
value shown on the LCD to match a
master gauge.
To access the Calibration menu, first
go to the Units menu.
Then, press and hold the shroud
Motor on/off button for 7 seconds. ENTRY CODE will appear
on the LCD.
Then, press and hold both the Down Arrow and Up Arrow
buttons for 7 seconds. CAL PT A will appear on the LCD.
See Table 2, "ZU4 Pressure Transducer Calibration", located
near the end of this document. Follow the steps in the table to
perform calibration procedures.
Screen 15
DIAGNOSE
00001
Screen 16
DIAGNOSE
01001
Press
PSI MPa
BAR Nm
Ft-lb
Screen 17
DIAGNOSE
10001
Press
PSI MPa
BAR Nm
Ft-lb
Screen 18
CAL PT A
SET
0
6.6 LCD Fault Conditions
Any fault condition will shut down the pump and prevent it
from starting.
6.6 A Clearing a Fault Condition from the LCD
PSI MPa
BAR Nm
After the fault causing problem has been corrected, clear the
Ft-lb
fault message from the LCD by disconnecting electrical power
from the pump. Wait until all characters clear the LCD (~ 20
seconds), then reconnect power.
6.6 B Power Off Fault
Display: "POWER OFF"
See Screen 19) The Power Off fault
occurs when the AC line power drops
to 65% or less of nominal voltage. The
pump will automatically shut-off the
valve solenoid and motor, and "Power
Off" will be displayed on the LCD.
Note: The Power Off message will also
appear for several seconds after the
pump has been disconnected from
electrical power.
6.6 C Button Fault
Display: "BUTTON FAULT"
(See Screen 20) The Button fault
occurs
when
detects that any button has been
pressed during the boot sequence
or if the shroud Motor on/off button
has been pressed for more than
3 seconds.
6.6 D Motor Overload Fault
Display: "MTR OVLD FAULT"
and "Motor Overload"
(See Screen 21) The Motor Overload
fault occurs when the electrical current
draw exceeds the pre-set limit of
the pump's internal circuit breaker.
The circuit breaker will automatically
reset in about 2 to 3 minutes after
the condition has been corrected.
However, before the pump can be
restarted, the operator must clear the fault by disconnecting
and reconnecting electrical power as described in Section 6.6 A.
PSI
6.7 LCD Low Voltage Warning
Display: "LOW VOLT" and
(See Screen 22) A "Low Voltage"
condition is defined as an operating
condition when the AC line power is
at or below 80% of nominal voltage.
While running the pump under this
condition, the "Low Voltage" signal will
flash on the LCD and the Low Voltage
hours will be counted and stored by
the microcontroller.
8
Screen 19
Screen 20
the
microcontroller
Screen 21
"Low Voltage"
Screen 22
LOW VOLT
POWER
OFF
BUTTON
FAULT
MTR OVLD
FAULT
MOTOR
OVERLOAD
LOW
VOLTAGE

Publicidad

loading