PUMP TO TANK CONNECTION (DISCHARGE PIPE)
1. Wrap thread tape around threads of a 1 in.
discharge tee (not included). Using a pipe
wrench, thread the 1 in. discharge tee into the
1 in. opening in the top of pump.
2. Install a 1 in. MPT x 1/4 in. FPT galvanized
bushing and (optional) pressure gauge (both
not included), or a pipe plug (not included). Do
not tighten, as you will prime pump later at this
location.
3. Wrap thread tape around the threads of a 1 in.
male PVC adapter (not included) and thread
the adapter into the discharge tee.
4. Continue with 1 in. fittings and pipe to
the pressure tank. An optional 1 in. union
(not included) is recommended for easy
connection and disconnection.
Copyright © 2019 Star Water Systems. All rights reserved.
10
1
1 in. Discharge Tee
2
Pressure Gauge or
Pipe Plug with Bushing
3
1 in. male PVC adapter
4
To pressure tank
1 in. union