OWNER'S MANUAL
5-Series Submersible Pumps
This submersible, multi-purpose pump is designed for clearwater transfer
applications and household water removal.
This pump series is available in manual and automatic models. The manual
pump can be converted to operate in automatic mode by installing a separate
liquid level control. The pump motor is equipped with an automatic resetting
thermal protector and may restart unexpectedly. Thermal Protector tripping
indicates motor overloading or overheating.
This product is covered by a Limited Warranty for a period of 1 year from the
date of original purchase by the consumer. For complete warranty information,
refer to www.LittleGiant.com.
Specifications
Voltage
HP
115
1/6
230
Flow Rates
1 ft (0.3 m)
1500 / 5678
SAFETY INSTRUCTIONS
This equipment should be installed and serviced by technically qualified personnel who are familiar with
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with
national and local electrical and plumbing codes and within Little Giant recommendations may result in
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product's application, limitations, and potential hazards. Read and follow instructions carefully to
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating instructions and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following
hazards:
Risk of death, personal injury, or property damage due to explosion,
fire, or electric shock.
•
Do not use to pump flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.
•
Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
•
Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
•
When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electrically disconnected.
•
If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of power.
PSI
Hz
11.4
60
Gallons/Liters per Hour at Height (Head)
3 ft (0.9 m)
5 ft (1.5 m)
1464 / 5542
1395 / 5281
Watts
Amps (FLA)
2.0
220
1.0
10 ft (3 m)
20 ft (6 m)
1191 / 4508
528 / 1999
EN
English
Breaker Amps
15
10
Shut Off
ft (m)
26.3 (8)