Assembly
16. For propane only
Correct hose connection.
WARNING!
Make sure that the hose does not come into contact with any
high temperature surface, or it may melt and leak causing a
fire.
Once the canister is placed inside the heater, secure it firmly
with the locking strap.
Leak test
WARNINGS!
A leak test must be carried out annually and every time a cylinder is connected or if part of
the gas system is replaced.
cylinder is connected or if a part of the gas system is replaced.
Never use an open flame to check for gas leaks. Make sure there are no sparks or open
flames in the area while checking for leaks.
Sparks or open flames can cause a fire or explosion, property damage, serious bodily injury
or death.
Tightness Test: Must be performed before first use, annually, and whenever any part using
any gas is replaced.
Components are replaced or repaired.
Do not smoke while performing this test and eliminate all sources of ignition. Refer to the
leak test diagram for areas to be checked. Turn all burner controls to the off position. Open
the gas supply valve.
Brush a solution of liquid soap and water halfway into all joints and connections of the re-
gulator, hose, manifolds and valves.
Bubbles will indicate a gas leak. Tighten the loose gasket or replace the part with one re-
commended by the service technician and have the patio heater inspected by a certified
gas fitter.
If the leak cannot be stopped, immediately turn off the gas supply,
disconnect and have the patio heater inspected by a certified gas fitter or dealer.
certified gas fitter or dealer. Do not use the patio heater until the leak has been corrected.
Regulator / hose connection
Connection of the regulator to the gas
cylinder