To help ensure safe and reliable operation, use only genuine Hilti spare parts, consumables and
accessories. Spare parts, consumables and accessories approved by Hilti for use with your product
can be found at your Hilti Store or online at: www.hilti.group
8
Transport and storage
Transport of cordless power tools and batteries
CAUTION
Accidental starting during transport !
▶ Always transport your products with the batteries removed!
▶ Remove the battery/batteries.
▶ Never transport batteries loose and unprotected. During transport, batteries should be protected from
excessive shock and vibration and isolated from any conductive materials or other batteries that may
come in contact with the terminals and cause a short circuit. Comply with the locally applicable
regulations for transporting batteries.
▶ Do not send batteries through the mail. Consult your shipper for instructions on how to ship undamaged
batteries.
▶ Prior to each use and before and after prolonged transport, check the product and the batteries for
damage.
Storage of cordless power tools and batteries
WARNING
Accidental damage caused by defective or leaking batteries !
▶ Always store your products with the batteries removed!
▶ Store the product and the batteries in a cool and dry place. Comply with the temperature limits stated in
the technical data.
▶ Do not store batteries on the charger. Always remove the battery from the charger when the charging
operation has completed.
▶ Never leave batteries in direct sunlight, on sources of heat, or behind glass.
▶ Store the product and batteries where they cannot be accessed by children or unauthorized persons.
▶ Prior to each use and before and after prolonged storage, check the product and the batteries for
damage.
9
Troubleshooting
If a problem occurs, always observe the status indicator of the battery. See the section headed Status
indicators of the Liion battery.
If the trouble you are experiencing is not listed in this table or you are unable to rectify the problem by
yourself, contact Hilti Service.
Trouble or fault
No hammering action.
The battery runs down more
quickly than usual.
The battery does not engage
with an audible click.
No response from the LEDs
on the battery.
*2373842*
Possible cause
The product is too cold.
Battery condition is not optimal.
The retaining lugs on the battery
are dirty.
Battery defective.
2373842
Action to be taken
▶ Bring the product into contact
with the working surface, switch
it on and allow it to idle. If
necessary, repeat the procedure
until the hammering mechanism
begins to operate.
▶ Call up the battery's state of
health. Section headed "Status
indicators of the Liion battery"
→ page 7.
▶ Clean the retaining lug and refit
the battery.
▶ Contact Hilti Service.