Full Programming Options
Menu Structure
Quickstart >
Tel. Numbers >
Alarm no.1
Alarm no.2
Alarm no.3
Alarm no.4
Tech.no.
Background no.
Call attempts
Settings
>
ID Code
Volume
System Config >
HW Monitoring >
Delays
>
COP delay
AS delay
Tech IP delay
Hangup delay
Answer delay
Redial del.
VAD timeout
Messages
>
Location
Reassurance
Guidance
Time/Date
>
Time
Date
Advanced
>
Passcode
Network ID
Next EN81 call
PBX Frequency
Language
Relay mode >
Relay override>
GMT Offset
Templates
Load Template
Save Template
Del. Template
Menu Sections explained...
Messages
Messages >
Time / Date
The time and date can be set by entering the correct values and
confirm by pressing
Advanced
Passcode
Enter the passcode required to enter standard programming mode
when EN81-28 mode is active. (up to 6-digits). From the idle screen
you will have to press * PASSCODE #
Network ID
Set an extension number 1-8 where units share a phone line. All unit
IDs on a system need to be unique.
Next EN81 call
Details the next scheduled Background call for the unit.
PBX Frequency
Sets disconnect tone frequency (40-2000Hz in 40Hz steps), if
connected to a PBX, which does not use standard tones.
Language
Tick the language required from the on-screen list provided.
>
Location
This is the only message that needs
recording. The location message is played
to the call centre receiving the alarm call,
to inform them of the location of the lift.
Reassurance
This is the message played to trapped
passengers as an alarm call is being
placed
Guidance
If the 'Guided' protocol has been
selected, this message will be played to
the call centre operator to ask them to
select whether to listen to the Location
message or to be connected to the lift car
immediately.
.