GB
Application
Prod. no. 36 249:
Single-hole mixer suitable for:
• Direct connection to cold water supply
• Connection to outlet of mixed water supply
Prod. no. 36 233 and 36 251:
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.
Technical Data
• Pressure
min. 0.5 bar / recommended 1 - 5 bar
• Operating pressure
• Test pressure
If static pressure is greater than 5 bar, fit a pressure-reducing
valve.
• Flow rate at 3 bar pressure:
• Supply voltage:
6 V-lithium battery (type CR-P2)
• Infinitely variable running time from 2 - 180 s
(factory setting: 15 s)
• Automatic safety shut-off after 180 s
• Type of protection:
Prod. no. 36 233 and 36 251:
• Temperature
Hot water inlet:
Recommended (energy saving):
• Water connection
Note
Avoid major pressure differences between hot and cold water
supply.
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Refer to the dimensional drawings on fold-out page I.
Flush pipes thoroughly before and after installation
(observe EN 806).
Lift rod (A) must be inserted into the mixer body during
installation, see fold-out page II, Fig. [1].
Fasten fitting to basin, see Figs. [1] to [3].
Connection, see Fig. [4].
In order to ensure permanent, trouble-free operation,
installation of the enclosed adapter with dirt strainer and
non-return valve is mandatory.
3
Open hot and cold water supply and check connections
for leakage.
Operation
After pressing the actuating cap (D), water flow is initiated for a
factory-adjusted running time of 15 s, see Fig. [2].
Renewed pressing during running time stops the water flow
immediately. Water flow is terminated automatically following
expiry of the set time.
Setting the running time
In order to change the running time, please proceed as
follows:
1. Activate adjusting mode by pressing the actuating cap (D),
see Fig. [2].
2. Hold actuating cap pressed; water flow commences after
pressing for 10 s.
3. Release the actuating cap after achieving the desired
running time (2 - 180 s).
max. 10 bar
4. Confirm the set time by pressing the actuating cap twice
16 bar
(double click) within 2 s.
The running time setting is confirmed by a short
water pulse (1 s).
approx. 6 l/min.
Automatic flushing (factory setting: not activated)
The automatic flushing serves to maintain water hygiene in the
case of long-term non-utilisation of the fitting and activates
water flow for 5 minutes, 3 days after the last use.
IP 59 K
Safety notes:
- Ensure free draining in the case of activated automatic
max. 70 °C
flushing.
60 °C
cold - right
Switching automatic flushing On / Off.
hot - left
Please proceed as follows:
1. Press actuating cap (D), see Fig. [2].
2. Release the actuating cap; water flow commences.
3. With water running, press the actuating cap again and hold
(approx. 5 s) until the water flow is interrupted for 1 s.
4. Continue to press and hold the actuating cap (approx. 5 s)
until the water flow is again interrupted for 1 s.
5. Continue to press the actuating cap (approx. 5 s) until the
water flow is again interrupted for 1 s.
6. By pressing the actuating cap twice (double click) within the
next 2 s, switch the automatic flushing on or off.
Pulsating water jet indicates the setting:
- 4 water pulses = Automatic flushing is switched on
- 2 water pulses = Automatic flushing is switched off
For each switching, the procedure must be repeated starting
from 1.
Setting continuous running time to 3.5 min or 11 min
Please proceed as follows:
1. Press actuating cap (D), see Fig. [2].
2. Release the actuating cap; water flow commences.
3. With water running, press the actuating cap again and hold
(approx. 5 s) until the water flow is interrupted for 1 s.
a) 3.5 min:
- Release actuating cap.
- By pressing the actuating cap twice (double click) within the
next 2 s, start continuous running for 3.5 min.