Control Panel

5
1.- On/off: Switching the unit On - Off and mode selection F4/ F0/ F5/ F1/ F2
2.- Temperature selector (15/ 27 ºC) and Air speed: Ambient temperature control and blower
speed (between 1st and 5th speed) manual mode only.
3.- Display: Screen showing the function selected and the status of the equipment.
4.- Time on F5 mode Selector: 30´
5.- Led : Moon On - indicates intermediate power
Sun On - indicates maximum power P0, p4 and f5
• On connection, the equipment checks the leds and
Special display messages
"Technical Control" Battery low (will bleep for 30 secs. and the unit will turn off)
:
Poor contact of the sensor recirculation wires or the sensor is damaged.
EO:
Poor contact of the anti-ice sensor or the sensor is damaged.
E6:
NP: F5 can not be selected after the pre-selected time of 30 minutes or 1 hour has elapsed.
(
This F5 function can only be re-activated if, keeping the unit working in mode P0 or P4, the engine
of the vehicle is running uninterruptedly during among 20 minutes -depending of the charge
or degradation level of the batteries-)
Turning the Equipment On
To turn the Minicool Compact Night & Day unit on, press the On/ Off key
always start up on the
To change the function, hold down the On/ Off key
release the key on obtaining the desired function.
4
3
(please see failure Diagnosis)
Function (Automatic Function).
F4
2
or 60´
automatic function.
f0,f4
-2 appears on the screen and turns off.
:
. The different functions will be displayed,