25
4.
Application
FLOW F series submersible pumps are suitable for pumping clear water (solids passage 1 mm).
The pump may not be used to pump corrosive, flammable, gaseous or potentially explosive fluids, or
sewage containing faecal matter. Fluids containing sand or other substances reduce the service life
of the pump. Not intended for condensation from condensing boilers and brine from water softening
systems.
ATTENTION!
This product is only suitable for removing clear water up to a water temperature of 40 °C or up to a
maximum of 60 °C during short-term operation.
The pump is for transportable installation only and is not in compliance with DIN EN 12056/12050
regulations for permanent fixed installation.
Our pumps are checked in accordance with EN 12050 LGA and conform to the current standards.
Also note that the maximum inlet temperature in the public sewer system is 35 °C and that you must
ensure that the water is cooled accordingly.
ATTENTION!
If damage can occur due to a failure of the pump, for example due to a power failure or technical
defect, an alternative system must be available as backup e. g. emergency power supply etc.).
ATTENTION!
Leakage of lubricants could result in pollution of the medium being pumped.