3. Installation Preparation.
To prevent personal injury and damage,
ensure that the hanging location allows the
blades a clearance of 7 feet (2.13m) from the
floor and 30in. (76cm) from any wall or
obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
This fan can be mounted with a downrod
on a regular (no-slope) or vaulted ceiling. The
hanging length can be extended by
purchasing a longer downrod (0.5in./1.27cm
diameter). Other installation, such as
flushmount, is not available for this fan.
Installation requires these tools:
Phillips screwdriver, flathead screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
4. Hanging Bracket Installation.
Turn off circuit breakers to current fixture from
breaker panel and be sure operating light switch is
turned to the OFF position.
WARNING: Failure to disconnect power supply prior
to installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be
sure the outlet box is securely attached to the
building structure and can support the full weight of
the fan. Ensure outlet box is clearly marked "Suitable
for Fan Support." If not, it must be replaced with an
approved outlet box. Failure to do so can result in
serious injury.
CAUTION: Be sure outlet box is grounded properly
and that a ground wire (GREEN or bare) is present.
Install hanging bracket to outlet box using original
screws, spring washers and flat washers provided
with new or original outlet box.* If installing on a
vaulted ceiling, face opening of hanging bracket
towards high point of ceiling. Arrange electrical
wiring around the back of the hanging bracket
and away from the hanging bracket opening.
*Note: It is very important that you use the proper
hardware when installing the hanging bracket as
this will support the fan.
blade edge
inches
7 feet
(76cm)
(2.13m)
downrod
installation
hanging bracket
outlet box screws
page 4
30
12ft - 20ft
(3.66m - 6.1m)
flushmount
installation
Vaulted ceiling
angle is not to
exceed 25 degrees.
flat washers