Descargar Imprimir esta página

GE GXK255TBN Manual Del Propietario E Instrucciones De Instalación página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT –
local inspector's use.
IMPORTANT –
public works department for plumbing codes.
You must follow their guides as you install the
Water Filtration system.
Note to Installer –
instructions with the Consumer.
Note to Consumer –
instructions for future reference.
• Skill level – Installation of this appliance requires
basic mechanical and electrical skills.
• Completion time – 60-90 minutes
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation is not
covered under the Warranty.
WARNING
Read "Important Safety
Information" on page 2 before beginning installation.
TOOLS AND MATERIALS
REQUIRED FOR INSTALLATION
• Phillips screwdriver
• Two (2) adjustable wrenches
• Electric drill and drill bit to drill 0.5" hole (type as
required) if mounting hole is needed for faucet
• Tape measure
• If your main water line is a rigid pipe, you will require
a compression fitting and possibly other plumbing
hardware to complete the installation (sold separately).
NOTICE — To avoid damaging the sink or counter
top, consult a qualified plumber or installer for drilling
procedures. Special drill bits may be needed for granite,
stone, porcelain or stainless steel.
CONTENTS INCLUDED WITH THE
PRODUCT
Water filter system assembly, including mounting
screws
Water line adapters and tubing
• Faucet
31-6000260 Rev. 3
Save these instructions for
Check with your local
Be sure to leave these
Keep these
• Teflon tape
-
Kitchen Faucet Filtration System GXK255TBN
CARTRIDGE SPECIFICATIONS
Performance Data – Filtration System
GXK255TBN Using Filter FQK2J
Rated/certified capacity = 300 gallons
Certified flow rate = 1.0 GPM
Performance data sheet is available at
gewaterfilters.com
COLD WATER CONNECTION
A typical connection using the included water supply
fitting is shown in the illustration below.
1. Close the cold water shutoff valve and open the
faucets to relieve pressure and drain water from
the sink cold water pipe.
2. Disconnect the existing cold water line from the
water shutoff valve.
cold water
pipe
water supply
fitting
gasket
cold water
shutoff
3. Make sure that the water supply fitting's gasket is
inside the female threaded portion of the fitting.
4. Install the water supply fitting onto the cold water
shutoff valve, where the existing cold water line
was removed, and hand tighten. Finish tightening
with two adjustable wrenches. Be careful not to
overtighten or cross thread as damage to threads
can occur. Some threads may be exposed when
adapter is fully seated.
5. Connect the existing cold water line to the male
threaded portion of the water supply fitting and
hand tighten. Finish tightening with two adjustable
wrenches. Be careful not to overtighten or cross
thread as damage to threads can occur. Some
threads may be exposed when adapter is fully
seated
Cold Water
Shutoff Valve
1/4" yellow
tubing to
inlet of the
filter system
5

Publicidad

loading