DESCRIPTION
- Single-phase control panel for roll-up doors. Compatible with HCS radio
transmitters.
- Protection of main feed and motor with fuse 6,3 A. LED indicator. ---
- External button input (STEP / STEP)
- Safety contact input and safety 8k2 input
INSTALLATION
Be sure mains are disconnected before proceeding with the installation.
DESCRIPTION OF TERMINALS
Power:
1.
Supply 230V ac -
2.
Supply 230V ac -
3.
Closing motor -
4.
Opening motor -
5.
Common motor -
6.
Power supply +12 VDC -
7.
Power Supply -12 VDC
8.
Safety contact
9.
Common motor
10.
P. Alt. external button (N.O.)
11.
safety band 8k2
N.C. Normally closed – N.O. Normally open
OPERATION
Automatism operations are performed by means of the external button connected
between terminal 9 and 10 or with an HCS radio control device. The operation ends
in case of one of the following conditions: at the activation of the corresponding limit
switch or at the end of the operating time. The control unit does not feature the
connection option for limit switches. The operating time can be set up to a maximum
of 2 minutes and 30 seconds (20 seconds by default), which is a safety time.
Also the automatic closing time, which controls the waiting time before the closing
operation is automatically performed, can be set up to a maximum of 3 minutes. The
same function is performed by an HCS transmitter and by the external button.
Pressing the transmitter (J2=open) or the external button will stop the door when it is
opening; pressing them twice will close it; pressing them one more time will stop it,
while a further pressure will close it and so on.
With J2 = CLOSED the transmitter works with 3 UP-STOP-DOWN buttons.
(Recommended for DEAD-MAN version)
11