OPTIONS SELECTION
DIP1 Sel. Timer / Auto closing:
ON automatic closing with timer.
OFF Automatic closing disabled.
DIP2 Programming timer
ON Operating time programming (DIP 1 OFF). Closing time
programming (DIP1 ON).
OFF Time programming disabled.
DIP3 Radio programming
ON radio programming of new transmitters enabled.
OFF radio programming disabled
DIP4 Dead-man
ON to close, press and hold the transmitter button or the external button. If the
button is not kept pressed, the operation is stopped.
OFF standard operation.
With J2 CLOSED keep the transmitter DOWN button pressed.
DIP5-6 disabling / enabling safety devices (photocells and wired or 8K2
contact strips)
DIP5
DIP6
ON
ON
ON
OFF
OFF
ON
OFF
OFF
JUMPER J2(near the microprocessor) 1 BUTTON or 3 BUTTONS (FOR CONTROL
UNIT LEARNING PRESS THE BUTTON B (STOP))
OPEN = operation with 1 button ( STEP MODE )( BY DEFAULT )
CLOSED = operation with 3 buttons ( UP-STOP-DOWN )( recommended in DEAD-
MEAN version )
Button A = up Button B = stop Button C = down
STORING TRANSMITTER CODE
To store the codes of the transmitters, the control unit must be in a stable condition
and the door closed.
Photocells and wired contact strips disabled (BY
DEFAULT)
Photocells and wired contact strips enabled
8k2 contact strip and photocells enabled
Photocell enabled - contact strip disabled
12