Reconditioning Switch
The charger is equipped with a switch on the bottom of the unit that
can be utilized to manually terminate the reconditioning process (as a
systemic, on-going use-case). However, the charger will continue to
provide an indication that the battery needs to be reconditioned.
Switch the RECONDITION to "ON" located at the bottom of the charger
to enable the recondition feature.
Troubleshooting
The IMPRES Adaptive Charger incorporates the features of:
• A universal input power supply
• A constant current rapid charger
• A negative pulse conditioning charger
• A reconditioning unit
• A 2-USB Type A Power Outputs
• A user selectable on/off switch for turning ON/OFF reconditioning.
The combination of the features listed above are unique in a desktop
charger. Therefore, operation of the radio with a battery attached while
in the charger is not recommended.
During the charging process, radio operation may result in minimally
reduced radio performance and extended battery charge time.
During the reconditioning process, the battery becomes fully
discharged. As a result, the radio may shut down during reconditioning
mode. It is recommended that the battery be calibrated without radio
attached or the attached radio to be turned off.
When troubleshooting, always observe the color of the LED.
13