Página 2
Table of Contents 1.0 Warnings and Important Information ....3 2.0 Description .............4 3.0 Application .............6 4.0 System Requirements ...........7 5.0 Installation and Use ..........8 6.0 Maintenance, Service, and Storage ....14 7.0 Inspection .............15 8.0 Labels ..............18 9.0 Definitions ............19 For purposes of this manual, the FT-X Cable Class 2 Leading Edge SRL-P in all iterations may be referred to collectively as the FT-X, the FT-X, the SRL-P, the leading edge SRL, the SRL, the equipment, the device, the product, or the unit.
Página 3
• Do not alter or intentionally misuse this equipment. • Consult FallTech when using this equipment in combination with components or subsystems other than those described in this manual. • Do not connect rebar hooks, large carabiners, or large snap hooks to the FBH dorsal D-rings as this may cause a roll-out condition and/or unintentional disengagement.
Página 4
2.0 Description The FT-X Cable Class 2 Leading Edge SRL-P is a self-retracting device for those working at height and may be subject to fall hazards, including leading edge hazards. This manual includes one Appendix containing figures and tables specific to the FT-X Cable SRL-P discussed in this manual.
Página 5
Additional testing has been conducted on a concrete edge substrate, outside and beyond the scope of ANSI Z359. Contact Falltech for more information on this testing.
Página 6
Full Body Harness (FBH). The SRD discussed in this manual may be used in non-overhead anchorage situations. Maximum permissible free fall in a typical PFAS is 6’ (1.8 m). Other applications may be below the D-ring, or horizontally in an approved FallTech SRL rotating anchor, designed for such use.
Página 7
Contact FallTech if you have any questions about compatibility. Connectors must be compatible with the anchorage or other system components.
Página 8
5.0 Installation and Use WARNING Do not alter or intentionally misuse this equipment. Consult FallTech when using this equipment in combination with components or subsystems other than those described in this manual. All components or subsystems used with the SRD discussed in this manual must be in compliance with ANSI Z359, CSA Z259, and/or OSHA.
Página 9
5.1 Installation to Full Body Harness Installation for both Single-leg and Twin-leg configurations of the FT-X Cable Class 2 Leading Edge SRL-P follow the same steps listed below: Step 1: On the FBH, lift the dorsal D-ring to the up-pointing position, then loosen the intersection of the two web straps that pass through the D-ring slot to create slacked loops of about 2”...
Página 10
action to avoid swing falls, which occur when the anchorage is not directly above the point where the fall occurs. Fall clearance and swing falls are subject to variable conditions. Anchor height, lateral movement, and setback distance all affect anchor location with regard to fall clearance and swing falls. The SRL may be attached to an overhead anchor, i.e., above the user’s FBH dorsal D-ring, or a non- overhead anchor, i.e., below the user’s FBH dorsal D-ring.
Página 11
Figure 7 - Twin-Leg SRL-Ps for Lateral Movement Avoid sudden or quick movements during the normal work operation, as this may cause the SRL pawl system to engage and possibly cause loss of balance, which may cause injury or death. If a fall occurs, the pawl system will engage and lock the lifeline.
Página 12
If a fall event occurs, remove it from service, and store it separately. Remove from service any unit that has been subjected to fall arrest forces or that exhibits damage consistent with such forces. For questions, contact FallTech. 5.3.4 Using the SRD: Do not use the SRD if inspection shows damage or any malfunction.
Página 13
Figure 9 - MRFC Overhead Anchorage Figure 10 - MRFC Non-Overhead Anchorage X-SRD Anchorage Height Above Dorsal D-ring Z- Minimum Required Fall Clearance From Y- Lateral Z- Minimum Required Working Surface Fall Clearance From Working Surface 28.0 Figure 11 - FT-X Minimum Required Fall Clearance for 130 to 310 lbs. (59 to 141 kg) Users Figure 4 - MRFC Non-Overhead Anchorage 1 foot (0.3 m) increments along the...
Página 14
5.4.4 FT-X with a Non-Overhead Anchorage Leading Edge Anchorage Application [310 to 420 lbs. (141 to 191 kg) user] Y- Lateral Z- Minimum Required The leading edge/below D-ring condition minimum required fall clearance (MRFC) is calculated using Fall Clearance From Working Surface five metrics, measured from the walking-working surface: SRD Deceleration Distance, D-Ring Shift and 28.0...
Página 15
Once removed from service, the SRD unit can be removed and replaced using the 5049 Spanner Tool. SRD unit replacement shall only be performed by a Competent Person or an Authorized FallTech Repair Center. Read and follow the Spanner Tool User Instruction Manual (448-00009).Failure to do so can cause the SRL to function improperly, which can result in serious injury or death.
Página 16
Table 2 - ANSI Z359.14-2021 SRL Inspection Recommendations Inspection Frequency Type of Use Application Examples Conditions of Use Competent Person Good Storage Conditions, Indoor or Rescue and Confined Infrequent Infrequent to Space, Factory Outdoor use, Room Annually Light Use Maintenance Temperature, Clean Environments Fair Storage Conditions, Indoor and...
Página 17
Inspection Record Model #:______________________ Serial #:_____________________ Date of Manufacture:__________________ INSPECTION PASS/ CORRECTIVE APPROVED INSPECTOR COMMENTS DATE FAIL ACTION NEEDED...
Página 18
8.0 Labels Product labels must be present and legible. 1) USER MUST INSPECT BEFORE EACH USE. 2) COMPETENT PERSON TO INSPECT AT LEAST ONCE EVERY (6) MONTHS. 3) IF UNIT FAILS INSPECTION, REMOVE FROM SERVICE. MARK ON DATE GRID ON BACK OF LABEL.
Página 19
9.0 Definitions The following are general definitions of fall protection terms as defined by ANSI Z359.0-2012. Anchorage: A secure connecting point or a terminating component of a fall protection system or rescue system capable of safely supporting the impact forces applied by a fall protection system or anchorage subsystem.
Página 20
Free Fall Distance: The vertical distance traveled during a fall, measured from the onset of a fall from a walking working surface to the point at which the fall protection system begins to arrest the fall. Harness, Full Body: A body support designed to contain the torso and distribute the fall arrest forces over at least the upper thighs, pelvis, chest and shoulders.
Página 21
APPENDIX A Table 1A: Specifications for FT-X Cable Class 2 Leading Edge SRL-Ps Working Lifeline Materials and Capacity and Model # Length Images Material Specifications Standards and Weight 82808SP0 Single User Capacity 82808SP0S for ANSI/CSA 82808SP1 8 ft. (2.4 m) Compliance: 82808SP2 Housing:...
Página 22
Table 1C: FT-X Cable SRL-LE CSA Performance Attributes Part #s and Typical Performance CSA Performance Requirements Conditions for 130 to 310 lbs. (59-141 kg) User 130 to 310 lbs. (59-141 kg) User Average Maximum Maximum Average Maximum Anchorage Deployment Part # Deployment Arrest Deployment...
Página 24
Índice 1.0 Advertencias e información importante ..25 2.0 Descripción ............26 3.0 Aplicación .............28 4.0 Requisitos del sistema ........29 5.0 Instalación y uso ..........31 6.0 Mantenimiento, servicio y almacenamiento ..37 7.0 Inspección ............38 8.0 Etiquetas ...............41 9.0 Definiciones ............42 A los fines de este manual, el FT-XTM Cable Class 2 Leading Edge SRL-P en todas las iteraciones puede denominarse colectivamente como el FT-X, el FT-X, el SRL-P, el SRL de borde delantero , el SRL, el equipo, el dispositivo, el producto o la unidad.
Página 25
• No modifique o utilice intencionalmente de manera equivocada este equipo. • Consulte con FallTech cuando pretenda utilizar este equipo en combinación con elementos o subsistemas diferentes a los descritos en este manual. • No conecte al anillo en “D” dorsal del FBH ganchos de barras de refuerzo, mosquetones grandes o ganchos de presión grandes, ya que esto puede provocar un lanzamiento y/o desenganche...
Página 26
antes de empezar a trabajar con él. NOTA: Para obtener más información, consulte el corpus normativo ANSI Z359 o CSA Z259. 2.0 Descripción El FT-X Cable Class 2 Leading Edge SRL-P es un dispositivo autorretráctil para aquellos que trabajan en altura y podrían estar sujetos a riesgos de caídas, incluidos los riesgos de borde delantero.
Página 27
Cuando se prueban dinámicamente de acuerdo con los requisitos de ANSI Z359.14-2021, los dispositivos autorretráctiles FallTech Clase 1 y Clase 2 tienen un AAF de 1.350 libras (6 KN) o menos y un AD de menos de 42” (1,1 m).
Página 28
El SRD descrito en este manual se puede usar en situaciones de anclaje no suspendido. La caída libre máxima permitida en un PFAS típico es de 6’ (1,8 m). Pueden considerarse otras aplicaciones por debajo del anillo en D, o de forma horizontal en un anclaje giratorio de FallTech SRL aprobado, diseñado para tal uso.
Página 29
Póngase en contacto con FallTech si tiene alguna pregunta sobre la compatibilidad. Los conectores deben ser compatibles con el anclaje u otros componentes del sistema. No utilice equipos que no sean compatibles, consulte la Figura 4.
Página 30
Figura 4 - Conexiones no compatibles Nunca conecte dos componentes activos (ganchos de seguridad o mosquetones) entre sí. Nunca conecte dos componentes activos (ganchos de seguridad o mosquetones) a un solo anillo en D al mismo tiempo. Nunca conecte de una manera que produzca una condición de carga en la puerta. Nunca lo sujete a un objeto de manera que la compuerta (del gancho de seguridad o mosquetón) no pueda cerrarse y bloquearse por completo.
Página 31
5.0 Instalación y uso ADVERTENCIA No altere ni haga mal uso intencional de este equipo. Consulte con FallTech cuando utilice este equipo en combinación con componentes o subsistemas distintos a los descritos en este manual. Todos los componentes o subsistemas utilizados con el SRD que se describen en este manual deben cumplir con ANSI Z359, CSA Z259 u OSHA.
Página 32
Figura 5 - Instalación de FT-X Cable Class 2 Leading Edge SRL-P Push 412-06112 Rev D 412-06112 Rev D 412-06112 Rev D 412-06112 Rev D 5.2 Conexión a un anclaje Examine el área de trabajo en busca de posibles peligros. Tome precauciones para evitar peligros elevados, como grúas, postes, cables eléctricos elevados y peligros en las superficies para desplazamiento/trabajo, como cables eléctricos, cables de soldadura, mangueras de aire y fluidos, incluidos los peligros de obstrucciones, como columnas verticales y pilas de materiales en el nivel...
Página 33
Figura 6: Redireccionar ángulo de borde delantero de cuerda de salvamento 5.3 Uso del FT-X Cable Class 2 Leading Edge SRL-P Antes de cada uso, inspeccione el FT-X Cable de acuerdo con la Sección 7. Retire el dispositivo de servicio si la inspección muestra daños o fallas. Colóquese el FBH (con el FT-X Cable conectado) de acuerdo con las instrucciones del fabricante del arnés.
Página 34
Retire de servicio cualquier unidad que haya estado sujeta a fuerzas de detención de caídas o que muestre daños consistentes con dichas fuerzas. Si tiene preguntas, comuníquese con FallTech. 5.3.4 Uso del SRD: No use el SRD si la inspección muestra daños o fallas.
Página 35
Evite movimientos bruscos o rápidos durante la operación normal de trabajo, ya que esto puede hacer que el freno del SRD se active y posiblemente cause pérdida de equilibrio y lesiones o la muerte. Si se produce una caída, el freno se aplicará y bloqueará la cuerda de salvamento. El EA se desplegará para detener la caída y limitar las fuerzas de detención del usuario.
Página 36
Figura 9 - Anclaje suspendido de MRFC Figura 10 - Anclaje no suspendido de MRFC X-SRD Anchorage Height Above Dorsal D-ring Z- Minimum Required Fall Clearance From Y- Lateral Z- Minimum Required Working Surface Fall Clearance From Working Surface 28.0 Figura 11 - Distancia despejada de caída mínima requerida de FT-X para usuarios de 130 a 310 libras (59 a 141 kg) Figure 4 - MRFC Non-Overhead Anchorage...
Página 37
5.4.4 FT-X con una aplicación de anclaje de borde delantero en anclaje no suspendido [usuario de 310 a 420 libras. (141 a 191 kg)] Y- Lateral Z- Minimum Required La distancia despejada de caída mínima requerida (MRFC) en condición del borde delantero/debajo Fall Clearance From Working Surface del anillo en D se calcula utilizando cinco métricas, medidas desde la superficie de desplazamiento y...
Página 38
5049. El reemplazo de la unidad SRD solo debe ser realizado por una persona competente o en un centro de reparación autorizado por FallTech. Lea y siga el Manual de instrucciones para el usuario de la llave inglesa (448-00009). De lo contrario, el SRL podría funcionar incorrectamente, lo que puede provocar lesiones graves o la muerte.
Página 39
7.4 Resultados de la inspección: Si una inspección revela defectos o daños en el equipo, mantenimiento inadecuado o indicadores de caída activados, retire el equipo del servicio. 7.5 Documento de inspección: Registre los resultados de la inspección en el Registro de inspección que se proporciona a continuación o en un documento similar.
Página 40
PLANILLA DE INSPECCIÓN No de modelo:______________________ No de serie:_____________________ Fecha de fabricación:__________________ Fecha de Pasó/no Se hace necesaria Aprobado Inspector Comentarios inspección pasó una acción correctiva...
Página 41
8.0 Etiquetas Las etiquetas deben estar presentes y ser legibles. 1) USER MUST INSPECT BEFORE EACH USE. 2) COMPETENT PERSON TO INSPECT AT LEAST ONCE EVERY (6) MONTHS. 3) IF UNIT FAILS INSPECTION, REMOVE FROM SERVICE. MARK ON DATE GRID ON BACK OF LABEL.
Página 42
9.0 Definciones Las siguientes son las definiciones generales de los términos que se utilizan en protección contra caídas según lo determina la norma ANSI Z359.0-2012. Anclaje: Punto de conexión seguro o extremo de un elemento integrante de un sistema de protección contra caídas o sistema de rescate, capaz de asimilar de forma segura las fuerzas de impacto que genera un sistema de protección contra caídas o subsistema de anclaje.
Página 43
Peligro de caída: Cualquier lugar en el que una persona está expuesta a la posibilidad de ocurrencia de caída libre. Caída libre: Acto de caer antes de que un sistema de protección contra caídas comience a generar resistencia para detener el movimiento. Distancia de caída libre: Distancia vertical que se recorre durante una caída, medida a partir del comienzo de ésta desde una plataforma de trabajo pedestre, hasta el punto en el que el sistema de protección contra caídas comienza a detener la caída.
Página 44
Apéndice A Tabla 1A: Especificaciones para FT-X Cable Clase 2 SRL-Ps Material de Longitud de Materiales y Capacidad y Modelo # cuerda de trabajo y Imágenes especificaciones estándares salvamento peso 82808SP0 Capacidad de un 82808SP0S solo usuario para el 82808SP1 8 pies (2.4 m) cumplimiento de ANSI/ 82808SP2...
Página 45
Tabla 1C: Atributos de rendimiento CSA de FT-X Cable Clase 2 SRL-P Requisitos de rendimiento de CSA para Rendimiento habitual para 130 a 310 No. de pieza y condiciones libras (59-141 kg) Usuario usuarios de 130 a 310 libras (59-141 kg) Fuerza de Fuerza de Fuerza de...
Página 47
Table des matières 1.0 Avertissements et informations importantes ..48 2.0 Description ............49 3.0 Utilisation .............51 4.0 Exigences du système .........52 5.0 Installation et utilisation ........54 6.0 Entretien, service et rangement ......60 7.0 Inspection .............61 8.0 Étiquettes .............64 9.0 Définitions ............65 Aux fins de ce manuel, le bord d’attaque SRL-P de classe 2 FT-XMC Cable dans toutes les itérations peut être désigné...
Página 48
• N’altérez pas l’équipement intentionnellement et utilisez-le correctement. • Consultez FallTech lorsque vous utilisez cet équipement en combinaison avec des composants ou sous-systèmes autres que ceux décrits dans ce manuel. • Ne pas connecter d’émerillon ou de gros mousqueton aux anneaux dorsaux en D du harnais corporel complet, car cela pourrait provoquer une condition de décrochage ou un...
Página 49
2.0 Description La SRL-P à bord d’attaque de classe 2 FT-X Cable est un dispositif auto-rétractable pour ceux qui travaillent en hauteur et peut être sujet à des risques de chute, y compris des risques de bord d’attaque. Ce manuel comprend une annexe contenant des figures et des tableaux spécifiques à la SRL-P FT-X Cable discutée dans ce manuel.
Página 50
Lorsqu’ils sont testés dynamiquement conformément aux exigences de la norme Z359.14-2021 de l’ANSI, les dispositifs auto-rétractables de classes 1 et 2 de FallTech ont une force d’arrêt moyenne de 612,3 kg/1 350 lb (6 KN) ou moins et une hauteur d’arrêt de moins de 1,1 m (42 po).
Página 51
Le DAR décrit dans ce manuel peut être utilisé dans des situations d’ancrage non aérien. La chute libre maximale autorisée dans un SAP typique est de 1,8 m (6 pi). D’autres applications peuvent être sous l’anneau en D ou horizontalement dans un ancrage rotatif de CSRA FallTech approuvé, conçu pour une telle utilisation.
Página 52
été conçus pour fonctionner ensemble de telle manière que leurs dimensions et leurs formes n’entraînent pas l’ouverture intempestive de leurs mécanismes de tête quelle que soit leur orientation. Pour toutes questions concernant la compatibilité, veuillez communiquer avec FallTech. Les connecteurs doivent être compatibles avec l’ancrage ou les autres composants du système. N’utilisez pas d’équipement qui n’est pas compatible, voir la Figure 4.
Página 53
Figure 4 - Raccordements non compatibles Ne jamais connecter deux composants actifs (mousquetons) ensemble. Ne connectez jamais deux composants actifs (mousquetons) à un seul anneau en D. Ne jamais brancher d’une manière qui entraînerait une charge sur le port. Ne jamais attacher à un objet d’une manière qui empêcherait la tête (du mousqueton) de se fermer et de se verrouiller complètement.
Página 54
5.0 Installation et utilisation AVERTISSEMENT N’altérez pas l’équipement intentionnellement et utilisez-le correctement. Consultez FallTech lorsque vous utilisez cet équipement en combinaison avec des composants ou sous-systèmes autres que ceux décrits dans ce manuel. Tous les composants ou les sous-systèmes utilisés avec le DAR dont il est question dans ce manuel doivent être conformes à...
Página 55
Figure 5 - Installation du bord d’attaque SRL-P de classe 2 FT-X Cable Push 412-06112 Rev D 412-06112 Rev D 412-06112 Rev D 412-06112 Rev D 5.2 Attacher à un ancrage Examinez la zone de travail pour détecter d’éventuels dangers. Veillez à éviter les dangers aériens tels que les grues, les poteaux, les câbles électriques aériens et les dangers liés aux surfaces de marche/ de travail tels que les câbles électriques, les fils de soudage, les tuyaux d’air et de fluide, y compris les risques d’obstruction tels que les colonnes verticales et les piles de matériaux au niveau inférieur.
Página 56
Figure 6 - Angle du bord d’attaque de la redirection de la corde de sécurité 5.3 Utilisation du bord d’attaque SRL-P de classe 2 FT-X Cable Avant chaque utilisation, inspectez le FT-X Cable conformément à la section 7. Mettez l’appareil hors service si l’inspection révèle des dommages ou un dysfonctionnement.
Página 57
Retirez du service toute unité qui a été soumise à des forces d’arrêt de chute ou qui présente des dommages compatibles avec de telles forces. Pour toute question, communiquez avec FallTech. 5.3.4 Utilisation du DAR: ‘utilisez pas le DAR si l’inspection révèle des dommages ou un dysfonctionnement.
Página 58
Éviter les mouvements brusques pendant le travail, car le frein du DAR risque de s’enclencher et de provoquer une perte d’équilibre et des blessures, voire la mort. Si une chute se produit, le frein s’engagera et verrouillera la ligne de vie. L’AE se déploie pour arrêter la chute et limiter la force d’arrêt sur l’utilisateur •...
Página 59
Figure 9 - Dégagement minimal requis en cas Figure 10 - Ancrage non aérien pour le dégage- de chute pour un ancrage aérien ment minimal requis en cas de chute (DMC) X-SRD Anchorage Height Above Dorsal D-ring Z- Minimum Required Fall Clearance From Y- Lateral Z- Minimum Required...
Página 60
5.4.4 FT-X avec une application d’ancrage de bord d’attaque d’ancrage non aérien [utilisateur de 141 à 191 kg (310 à 420 lb)] Y- Lateral Z- Minimum Required Le dégagement de chute minimum requis (DCMR) du bord d’attaque/sous l’anneau en D est calculé à Fall Clearance From Working Surface l’aide de cinq mesures, mesurées à...
Página 61
5049. Le remplacement du DAR ne doit être effectué que par une personne compétente ou un centre de réparation FallTech agréé. Lisez et suivez le manuel d’instructions de l’utilisateur de l’outil clé (448-00009). Le non-respect de cette consigne peut entraîner un mauvais fonctionnement de la CSRA, ce qui peut entraîner des blessures graves ou la mort.
Página 62
7.4 Résultats d’inspection: Si une inspection révèle des défauts ou des dommages à l’équipement, un entretien inadéquat ou des indicateurs de chute activés, mettez l’équipement hors service. 7.5 Inspection du document: Inscrire les résultats de l’inspection dans le registre d’inspection fourni ci-dessous ou dans un document semblable.
Página 63
Registre d’inspection No de modèle:______________________ No de série:_____________________ Date de fabrication:__________________ DATE D’IN- SUCCÈS/ MESURES CORREC- APPROUVÉ INSPECTEUR COMMENTAIRES SPECTION ÉCHEC TIVES NÉCESSAIRES...
Página 64
8.0 Étiquettes Les étiquettes doivent être présentes et lisibles. 1) USER MUST INSPECT BEFORE EACH USE. 2) COMPETENT PERSON TO INSPECT AT LEAST ONCE EVERY (6) MONTHS. 3) IF UNIT FAILS INSPECTION, REMOVE FROM SERVICE. MARK ON DATE GRID ON BACK OF LABEL.
Página 65
9.0 Définitions Les termes généraux reliés à la protection contre les chutes, tels que définis par l’ANSI Z359.0-2012, se présentent comme suit: Ancrage: Un point de connexion sécurisé ou un composant terminal d’un système de protection contre les chutes ou d’un système de sauvetage capable de supporter en toute sécurité les forces d’impact appliquées par un système de protection contre les chutes ou un sous-système d’ancrage.
Página 66
Composant: Un élément ou un ensemble intégral d’éléments interconnectés destinés à remplir une fonction dans le système. Sous-système de raccordement: Un assemblage, y compris les connecteurs nécessaires, composé de tous les composants, sous-systèmes, ou les deux, entre l’ancrage ou le connecteur d’ancrage et le point d’attache du harnais.
Página 67
Annexe A Tableau 1A : Spécifications du SRL-P de classe 2 FT-X Cable Longueur no du Matériel de la Matériels et de travail et Capacité et normes Images modèle ligne de vie spécifications poids 82808SP0 82808SP0S Capacité d’utilisateur 82808SP1 2,4 m (8 pi) unique pour la 82808SP2 conformité...
Página 68
Table 1C : Attributs de performance du SRL-P de classe 2 FT-X Cable selon la CSA Exigences de performance de la CSA pour Numéro des pièces et Performance typique pour l’utilisateur l’utilisateur de 59-141 kg (130 à 310 lb) conditions de 59-141 kg (130 à...