INSTALLATION
Install on the Desktop
1. Place the bottom of switch on a sufficiently large and
stable table.
2. Peel off the rubber protective paper of the four footpads
one by one, and stick them in the corresponding circular
grooves at the four corners of the bottom of the case.
3. Flip the switch over and place it smoothly on the table.
Install on the Wall
Note: GWN7801(P) require the Extended Rack Mounting Kits.
1. Use the matching screws (KM 3*6) to fix the two L-shaped
rack-mounting kits (rotated 90°) on both sides of switch.
2. Stick the switch port up and horizontally on the selected
wall, mark the position of the screw hole on the L-shaped
rack-mounting kits with a marker. Then, drill a hole at the
marked position with an impact drill, and drill the expansion
screws(prepared by yourself) into the drilled hole in the wall.
3. Use a screwdriver to tighten the screws (prepared by
yourself) that have passed through the L-shaped rack-
mounting kits to tighten the expansion solenoids to ensure
that the switch is firmly installed on the wall.
Install on a 19" Standard Rack
Note: GWN7801(P) require the Extended Rack Mounting Kits.
1. Check the grounding and stability of the rack.
2. Install the two L-shaped rack-mounting in the
accessories on both sides of switch, and fix
them with the screws provided (KM 3*6).
3. Place the switch in a proper position in the rack
and support it by the bracket.
4. Fix the L-shaped rack-mounting to the
guide grooves at both ends of the rack with
screws(prepared by yourself) to ensure that the
switch is stably and horizontally installed on the
rack.
Note:
To avoid high temperatures and keep
Air inlet
the device cool, sufficient space should
be left around the switch for heat dissi-
pation. The air inlet of the switch cannot
face or be close to the air outlet of other
devices.
Rubber footpads
Circular groove
Back of the Switch
GWN7802P
Fan
Back side
Air outlet
~ 5 ~
ACCESS & CONFIGURE
Note: If no DHCP server is available, the GWN7800 default IP address is 192.168.0.254.
Method 1: Login using the Web UI
1. A PC uses a network cable to correctly connect any RJ45 port of the switch.
2. Set the Ethernet (or local connection) IP address of the PC to 192.168.0.x ("x" is any value between 1-253), and
the subnet mask to 255.255.255.0, so that it is in the same network segment with switch IP address. If DHCP is
used, this step could be skipped.
3. Type the switch's default management IP address http://<gwn7800_IP> in the browser, and enter username and
password to login. (The default administrator username is "admin" and the default random password can be found
at the sticker on the GWN7800 switch).
Method 2: Login using the Console port
1. Use the console cable to connect the console port of switch and the serial port of PC.
2. Open the terminal emulation program of PC (e.g. SecureCRT), enter the default username and password to login.
(The default administrator username is "admin" and the default random password can be found at the sticker on
the GWN7800 switch).
Method 3: Login Remotely using SSH/Telnet
1. Turn on the Telnet of the switch.
2. Enter "cmd" in PC/Start.
3. Enter telnet <gwn7800_IP> in the cmd window.
4. Enter the default username and password to login. (The default administrator username is "admin" and the default
random password can be found at the sticker on the GWN7800 switch).
Method 4: Configure using GWN.Cloud / GWN Manager
Type https://www.gwn.cloud (https://<gwn_manager_IP> for GWN Manager) in the browser, and enter the
account and password to login the cloud platform. If you don't have an account, please register first or ask the
administrator to assign one for you.
Air inlet
The GNU GPL license terms are incorporated into the device firmware and can be accessed via the Web user interface of the
device at my_device_ip/gpl_license. It can also be accessed here: https://www.grandstream.com/legal/open-source-software To
obtain a CD with GPL source code information please submit a written request to: info@grandstream.com
Air inlet
GWN7803P
Fan
Air outlet
Refer to online documents and FAQ for more detailed information:
https://www.grandstream.com/our-products
~ 6 ~
Air inlet
Back side