If the user wants to restore the function and start a new learning period it is necessary to press the "SET"
button for 10 seconds (the ECO LED will flash).
If the ECO function is active and the "SET", button is pressed, the function will be disabled and the cor-
responding selected temperature will be visualized (40°C -> 80°C).
THERMAL DISINFECTION CYCLE function (anti-legionella)
The anti-legionella function is activated by default. It consists of a heating/maintenance cycle of the wa-
ter at 65°C for 1h so as to carry out thermal disinfection action against the relevant bacteria.
The cycle starts at the first ignition of the product and after each re-ignition which follows a lack of mains
power. If the product always works at a temperature below 60°C, the cycle is repeated after 30 days.
When the product is off, the anti-legionella function is not active. If the appliance is switched off during
the anti-legionella cycle, the product turns off and the function is not completed. At the end of each
cycle, the operating temperature returns to the value set previously by the user.
The activation of the anti-legionella cycle is displayed by the ON LED SET. To deactivate or activate the
anti-legionella function, press and hold the button ON/OFF " " ed the "SET" key for 3 sec, to confirm
deactivation the 40 °C LED flashes rapidly for 3 sec. To reactivate the anti-legionella function, repeat the
operation described above; to confirm that reactivation has taken place, the 60 °C LED flashes rapidly
for 3 seconds.
Warning: when this software has been carrying out the thermal disinfection treatment, water temperature can
cause burns. Feel water before bathing or showering.
WI-FI FUNCTION
For further information about Wi-Fi configuration and the product registration procedure, refer to the
enclosed quick start guide dedicated to connectivity, or visit the website:
https://discover.ariston-net.remotethermo.com
Connection status description
Slow flashing
Wi-Fi
Rapid flashing
Button
Double flashing
ON
OFF
Wi-Fi RESET: to carry out a reset, press the"
WEEKLY PROGRAM FUNCTION
The weekly program function can only be activated through the App.
Two different setpoint temperatures at two different times can be selected for each day of the week: the
product will calculate the heating speed and, depending on the temperature, the best moment to start
heating in order to reach the setpoint at the desired time.
Press the "SET" button to deactivate the function.
BOOST FUNCTION
The BOOST function is activated/deactivated through the APP.
The Boost function temporarily sets the setpoint temperature at 80° bypassing the previous operating
mode and self-deactivates once the setpoint is reached. In this way, the maximum amount of hot water
will be available. The Boost function is automatically deactivated in the event of: blocking error; if the
appliance is in "OFF"; or if the "SET" button is pressed to change the setpoint.
18 / EN
The Wi-Fi module is ON
The Wi-Fi module is in Access Point mode
The WI-Fi module is connecting to the home network
The Wi-Fi is ON and connected to the home network
The Wi-Fi module is OFF
" and "