Dry vacuuming without paper filter bag (Fig. F}
When dry vacuuming without paper filter
bag,
fit the special filter bag (F 2) with the water
suction device (F 1)
Wet vacuuming (Fig. E)
Fit
water suction device (E 1) in place of the
it firmly against the suction lank wall. Insert
protective filter (D
1). Mount suction
head so
that the mains cable is routed opposite the
connector.
Assemble suction hose, hand pipe
and
nozzle.
Use only original Wetrok paper filter bags.
3.2 Operating
Preparation of the equipment
Make sure that the voltage indicated on the
identification plate is the same as that available
in the
building.
The machine is earthed and
has an earth wire.
Preparation for work
Dry vacuuming with paper filter bag (Fig. D).
The Wetrok Silento 5000 can be fitted with a
paper filter bag.
Fitting the paper filter
bag:
Unfold paper filter
bag (D
2).
Pull the rubber flange (0 3) from
below on to the suction connection and press
12
Warning: Ensure lhat the power supply cable
is not damaged by being run
over,
crushed or
dragged
along.
3. Operating
3.1.
Saftey instructions
• Whilst in
operation,
caution is to be exer
cised in respect to third
parties,
especially
children.
• When cleaning and servicing the machine or
changing parts, pull out the mains connector
plug.
Make sure that lhe
power
supply cable is in a
servi
c eable
condition.
2.5 Operating for the first time
Delivery,
instructions on safely
rules,
handling
and
maintenance,
as well as operation
for
the
first time is normally carried
out
by a specialist
approved by Wetrok.
Where this is not the
case,
the operator is
responsible for instructing the users.
Further saftey instructions concerning
operating and maintenance are detailed in
the relevant sections and must be complied
with!
2.4 Emergencies
In the case of an
emergency:
• Pull out the mains connector
plug.
• Immediately apply recognised firstaid
measures.
After
incidents,
do not resume operation with
lhe machine until it has been inspected by
Wetrok.
• responsibilities for the
operation, mainten
ance and repair of the machine are clearly
assigned and observed.
• faults and damage are immediately notified
lo the Wetrok Service Agent.
2.3
Organisational points
It is the responsibility of the operator to ensure
lhal:
• the machine is used only by personnel who
have been instructed in its handling and
authorized to use it.
• the recognised occupational safety regula
tions are
observed.
• any further
national
or international company
regulations are
observed.
• all users are accquainted with the safety
regulations and trained in the use of the
specific machine.
• all users have read and understood the
operating
instructions.
with
the following prescriptions is
prohibited:
• Protective devices must not be removed or
bypassed.
• Conversions and modifications to the
machine are not permitted.
• Defective supply cables are only to be
replaced by PVC flexible sheathed cables
H 05
VV.
• The machine is to be fitted with a type H
circuit breaker for a rated current of
10
A
or
10 A
fuse
link.
2.2 Improper usage
Any usage of the machines for a purpose not
covered
under
the «Prescribed
use»
or the
contractually agreed purpose is not
permissible.
The use of the machine in an
unserviceable condition or not in compliance
2.1. Source of danger
Electrical voltage
I
electric current
Warning:
Danger!
Contact with voltage or current carrying parts
carries the risk of electric shock, which can
result in serious injury or even
death.
Never
Louch damaged
cables.
Always switch off and
disconnect the power supply before carrying
out any work on the
machine.
Replace faulty
cables
immediately.
2. General safety instructions
The machine is designed and constructed
according to the present state of the art and
recognised technical safety
standards.
It is
electrically tested and satisfies European
Saftey Standards.
Dangers can occur in spite of
this,
in particular
in the case of maloperation or noncompliance
with the specifications and information in the
operating
instructions.
Nozzle with rollers
29
Floor nozzle
38
Combination nozzle 43
Pipe cleaning nozzle 26
Radiator brush nozzle 32
Pointed rubber nozzle
33
Oust brush nozzle 39
Crevice nozzle 41
Crevice nozzle 40
Nozzle set 44 (comprising
connector,
crevice
nozzle,
hand
nozzle,
radiator brush
nozzle,
dust brush nozzle and
brush
nozzle)
Vacuumat
nozzle;
extra wide suction
nozzle,
69 cm
wide,
for wet and dry vacuuming
II. Accessories (Fig. H)
Suction hose
9,
2,5 m long 0 32 mm
Suction
hose
23,
3
m long
0 38
mm
Suction hose
15,
3,2 m long 0 50 mm
Suction pipe
85,
0 32
mm
Suction pipe
86, 0 38
mm
Suction pipe
51,
0
50 mm
Extension pipe
83,
0 32
mm
Connector V 18, 0 32 mm
Reducer V
37,
0 38/32
mm
Waler suction nozzle
21
Water suction nozzle
42
Nozzle with rollers 24
Nozzle with rollers 25
1. Machine description
I. Machine components
A 1. Suction head with suction motor
A 2.
Tumbler switch for suction motor
A 3. Clamping catch on both sides
A
4.
Plugin sleeve for connecting suction hos
A
5.
Suction tank
A
6.
Tumbler handle
A 7. 2 swivelling wheels
A
8.
2 transport wheels
A
9.
Tilting structure
A
10.
Mains cable
A
11.
Handle for suction head
representing a health hazzard
is not permissible and is forbidden on account
of the associated dangers.
• removing any types of dust that may be
dangerous to health
• vacuuming any flammable,
poisonous,
caustic,
irritating or other substances
This machine is designed
for
professional
dry
and wet vacuum cleaning indoors according to
the operating
instructions.
Any other usage, in particular
Prescribed use
The foldout page contains photos which are
referred to in the description of the
machine.
Wetrok Silento 5000/50. They must be stored
near the machine or machine
location
and
be accessible to the operator at all
times.
These operating
instructions provide you with
all information
necessary for the
proper,
safe
and prescribed use and maintenance of the
About this document
Operating Instructions
(GB}