Descargar Imprimir esta página

BFT Michelangelo BT A 60 Instrucciones De Uso Y De Instalacion página 47

Automatismos electromecanicos para barréras vehicular

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 68
15.8) PASSWORD MENU (PASSWORD)
Used to set a password for the board's wireless programming via the U-link
network.
With "PROTECTION LEVEL" logic set to 1,2,3,4, the password is required to
access the programming menus. After 10 consecutive failed attempts to log
in, you will need to wait 3 minutes before trying again. During this time,
whenever an attempt is made to log in, the display will read "BLOC". The
default password is 1234.
16) CONNECTION WITH EXPANSION BOARDS AND UNIVERSAL HANDHELD
PROGRAMMER VERSION> V1.40 (Fig. M) Refer to specific manual.
WARNING! Incorrect settings can result in damage to property and injury to people
and animals.
17) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
(Fig. N)
17.1) Opposite Barriers
Refer to the U-link instructions for the modules.
NOTE: On the board set as the Slave, the Safety Edge input (Safety Edge/ Test
Safety Edge/ 8k2 Safety Edge) should only be set to SAFE2.
TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
0
180
TCA
1
180
TRF. L GHT. C LR. T
10
240
alar ti e
o p e n . c a l i b .
0
100
(Special par. 1)*
c l o s . c a l i b .
0
100
(Special par. 2)*
accel.
1
99
(Special par. 6)*
1
99
OP. F ORCE
1
99
CLS. F ORCE
0
85
BRAKE
75
99
e er. b ra e
15
50
Op. speed
15
50
cl speed
0
250
Maintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
(***)=Reference for universal handheld programmer.
TABLE "B" - LOGIC - (LOGIC)
Logic
Definition
Automatic Closing
TCA
Time
Fast closing
FAST CLS.
INSTALLATION MANUAL
Default
Personal
Definition
10
Automatic closing time [s]
Time-to-clear traffic light
40
zone [s]
Alarm time
30
Opening value calibration
82
21
Closing value calibration
Acceleration
75
Leaf force during opening
85
Leaf force during closing
85
50
Braking [%]
75
Emergency braking
50
Speed during opening
50
Speed during closing
Programming number of
operations for maintenance
0
threshold
[in hundreds]
Cross out
Default
setting
used
0
1
 
1
0
0
 
1
18) RESTORING FACTORY SETTINGS (Fig.
WARNING: this operation will restore the control unit's factory settings and all
transmitters stored in its memory will be deleted.
WARNING! Incorrect settings can result in damage to property and injury to
people and animals.
- Cut off power to the board (Fig.
- Open the Stop input and press the - and OK keys together (Fig.
- Switch on the board's power (Fig.
- The display will read RST; confirm within 3 sec. by pressing the OK key (Fig.
- Wait for the procedure to finish (Fig.
- Procedure finished (Fig.
19) PARKING MANAGEMENT SYSTEM CONNECTION
The board has an output for the control of the barrier status configured this
way (Fig. I4).
The logic must be set to AUX3/AUX0=12 .
closed contact between terminals 26-27 with the barrier lowered
open contact between terminals 26-27 with the barrier not lowered.
Description
Waiting time before automatic closing.
Time-to-clear for the zone run through by traffic controlled by the traffic
light.
If an obstacle is sensed or the photocells are engaged for longer than the set
[s]
time, contact 26-27 closes. The contact is then opened by the Stop command
or by the closing limit switch. Active only by setting the AUX3=5 logic.
Opening value calibration [%]
Set the reference value from 0,0 to 100,0 for the required opening position
(see Paragraph Limit Switch Setting).
Closing value calibration [%]
Set the reference value from 0,0 to 100,0 for the required closing position
(see Paragraph Limit Switch Setting).
Acceleration [%]
Set the acceleration to be applied at the beginning of each movement.
Force exerted by the barrier while opening.
WARNING: It affects impact force directly: make sure that
current safety requirements are met with the set value (*).
[%]
Install anti-crush safety devices where necessary (**).
Force exerted by the barrier while closing.
WARNING: It affects impact force directly: make sure that
current safety requirements are met with the set value (*).
[%]
Install anti-crush safety devices where necessary (**).
Opening speed/Closing [%]
Set the numerical value of the speed: 1% corresponds to the slow-down
speed, 99% to the maximum speed.
Emergency braking [%]
Set a value from 75% to 99% for the braking intensity in case of reversing
movement or emergency braking: any values lower than those set in the
"braking" parameter will be ignored.
Running speed during opening [%]
Sets the running speed that the barrier must reach during opening, as a
percentage of the maximum speed the actuator can reach.
Running speed during closing [%]
Sets the running speed that the barrier must reach during closing, as a
percentage of the maximum speed the actuator can reach.
Allows you to set a number of operations after which the need for main-
tenance will be reported on the AUX output configured as Maintenance
or Flashing Light and Maintenance .
Logic not enabled
Switches automatic closing on
Logic not enabled
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
O
)
O
ref.1)
O
ref.3)
O
ref.5)
O
ref.6)
Optional extras
MICHELANGELO BT A-
O
ref.2)
O
ref.4)
47

Publicidad

loading

Este manual también es adecuado para:

Michelangelo bt a 80Michelangelo bt a 60