Electrical Installation
All oven models are designed to be connected to either a 208 V or 240 V AC, 60 Hz,
3-wire single-phase power supply.
Model
Circuit Required
208 V, 60 Hz
240 V, 60 Hz
MES301HS
max. 15 AMP
max. 15 AMP
MES301HP
max. 15 AMP
max. 15 AMP
Electrical Connection
12
The electrical supply should be a 3-wire single-phase AC. Install a suitable conduit
box (not furnished).
Important - Local codes may vary; installation, electrical connections and
grounding must comply with all applicable local codes.
1. Connect the red oven wire to the red electrical supply wire (hot wire).
2. Connect the black oven wire to the black electrical supply wire (hot wire).
3. Connect the yellow/green ground oven wire to the bare ground electrical supply
wire.
Attach flexible conduit to the junction box.
To facilitate serviceability, the flex conduit must not be shortened and should be
routed to allow for temporary removal of the oven.